Trouble 4:
Oven operates with little or no heat.
Troubleshooting Procedures (Electronic Models)
Output 
performance 
is low.
Check the power 
supply voltage.
Lower than 
90% of rated 
voltage.
Decrease in 
supply voltage 
under load.
Customer must 
contact local 
power 
company or 
qualified 
electrician.
Normal
Disconnect wire leads 
from relay RY2 and 
verify on and off times.
Abnormal
Normal
Failed 
controller.
Replace 
controller.
Abnormal
Failed 
magnetron
Replace 
magnetron.
Measure the 
output power.
NOTE: Simple test of power output can be conducted by heating one liter of water for one minute.
Refer to Power Test on page 24 of this manual.