Maytag RCS 사용자 설명서

다운로드
페이지 36
Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 
 
©2004 Maytag Services
 
16023293   Rev. 0 
23
 
TAB 1
TAB 2
RLY 3
1
9
3
5 4
8
C 1
N
1
2
 
Function 
Test Set-Up / 
Condition 
Meter 
Setting 
Probe Placement 
Results 
Power to current 
transformer 
All Conditions 
Volts 
Tab 1 to CN1 Pin 3 (Neutral) 
120 VAC 
Power from current 
transformer 
All Conditions 
Volts 
Tab 2 to CN1 Pin 3 (Neutral) 
120 VAC 
Power from Oven TCO  All Conditions 
Volts 
CN1 – Pin 1 (Black wire to Neutral) 
120 VAC 
Power to Oven Light 
Standby.............  
Ready................  
Cook .................  
Volts 
Volts 
Volts 
CN1 – Pin 4 to Pin 1 .............................  
CN1 – Pin 4 to Pin 1 .............................  
CN1 – Pin 4 to Pin 1 .............................  
120 VAC 
0 VAC 
0 VAC 
Power to Blower Motor 
Standby.............  
Ready................  
Cook .................  
Volts 
Volts 
Volts 
CN1 – Pin 5 to Pin 1 .............................  
CN1 – Pin 5 to Pin 1 .............................  
CN1 – Pin 5 to Pin 1 .............................  
120 VAC 
0 VAC 
0 VAC 
Secondary Interlock 
Switch 
Door Closed ......  
Door Opened ....  
Ohms 
Ohms 
CN1 – Pin 8 to Pin 9 .............................  
CN1 – Pin 8 to Pin 9 .............................  
Continuity 
Infinite 
Power to Relay 3 
Standby.............  
Ready................  
Cook .................  
Volts 
Volts 
Volts 
Relay 3 – Pin 1 to Pin 2.........................  
Relay 3 – Pin 1 to Pin 2.........................  
Relay 3 – Pin 1 to Pin 2.........................  
120 VAC 
120 VAC 
0 VAC