Maytag ACO1530AW 사용자 설명서

다운로드
페이지 43
Troubleshooting Procedures
©2002 Maytag Appliances Company
13
16021668    Rev. 0
Key pad matrix is located in
“Testing Procedures” on page 11.
"PLEASE TOUCH TIME OF DAY" 
does not appear in 
the display, 
when unit is plugged in.
Is 120 volts 
indicated.
Replace 
circuit 
board.
Verify proper 
connection of 
circuit board.
YES
NO
Unit operates.
1. Check power supply.
2. Check fuse.
3. Check oven thermostat.
Display does not 
indicate correct number 
pressed or correct 
indication when 
programmed.
Is continuity 
indicated when 
key pad is 
pressed.
Verify proper 
connection of 
ribbon 
connector.
Replace 
control 
key pad.
NO
YES
Unit operates.
Does ribbon 
connector have 
proper 
connection.
Replace 
circuit 
board.
    Reconnect 
ribbon connector 
for proper 
connection.
YES
NO
Measure voltage 
between pin 1 
and pin 3 of 
CN1 connector
Measure resistance 
of control key 
panel after removing 
ribbon connector.