Troubleshooting Procedures
16021668   Rev. 0
16
©2002 Maytag Appliances Company
Check:
1. Primary and Secondary Interlock Switches.
2. Thermostat.
Unit does not heat even 
if display counts down 
when START pad is 
pressed for high power.
Does relay 
contacts measure 
correct resistance.
Verify proper 
connection of 
ribbon 
connector.
NO
YES
Unit operates.
Replace 
circuit 
board.
Does ribbon 
connector have 
proper 
connection.
Replace 
circuit
board.
    Reconnect ribbon 
connector for 
proper 
connection.
YES
NO
Does transformer 
have the correct 
resistance.
Replace 
high 
voltage 
diode.
NO
YES
Unit operates.
Does capacitor 
have correct 
resistance.
Measure 
resistance of high 
voltage diode. 
See to 
Testing Procedures 
on page 10.
YES
Does diode 
have correct 
resistance
Replace 
magnetron.
NO
Replace 
high voltage 
transformer.
Measure 
resistance of high 
voltage capacitor. 
See to 
Testing Procedures 
on page 10.
YES
Check the 
contacts of 
RY2 relay.
Unit does not heat even 
if display counts down 
when START pad is 
pressed for high power.
Measure resistance of 
high voltage transformer. 
See to Testing
 Procedures on page 10.
Replace 
high voltage 
transformer.
NO