Maytag ACO1860AC 사용자 설명서

다운로드
페이지 43
Troubleshooting Procedures
©2002 Maytag Appliances Company
15
16021668    Rev. 0
Check:
1. Air Vents.
 Does fan motor 
  operate when 
START is 
pressed.
   Measure 
  resistance 
of high voltage 
  capacitor.
Replace 
thermostat.
NO
YES
Unit operates.
Does capacitor have
 correct resistance. 
 See to Testing 
 Procedures on 
      page 10.
Replace 
magnetron.
Replace high 
   voltage 
  capacitor.
YES
NO
Does 
fan motor 
operate.
Measure 
resistance 
of fan motor, 
approximately 
38 ohms.
Is the resistance
of fan motor 
correct.
Replace 
circuit 
board.
Replace 
fan motor.
NO
NO
YES
YES
Check if fan motor 
  operates when 
START is pressed.
Place a jumper 
wire across 
thermostat.
Unit operates normal, 
but little or no heating 
is produced with an 
oven load.