Sanyo CG1411 사용자 설명서

다운로드
페이지 100
2
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are
Cooling: Indoor air temperature
80°F D.B. / 67°F W.B.
Outdoor air temperature 95°F D.B. / 75°F W.B.
Heating: Indoor air temperature
70°F D.B.
Outdoor air temperature 47°F D.B. / 43°F W.B.
2.  SPECIFICATIONS
2-1.  Unit Specifications
Indoor unit
KGS1411
Outdoor unit
CG1411
Power Source
Cooling
Heating
Electric power source
115V 60Hz
Employed gas
Natural gas (LP)
Performance
Cooling
Heating
Capacity
kW
2.58
4.1 / 2.9 / 1.8
8,800
14,000 / 9,900 / 6,150
Air circulation (High)
ft
3
/min (m
3
/min)
282 (8.0)
300 (8.5)
Moisture removal (High)
Pints/h
2.2
Electrical Rating
Cooling
Heating
Available voltage range
V
104 – 126
Running amperes
A
8.2
5.9
Power input
W
900
620
Power factor
%
95
91
SEER
BTU/W
10.0
Compressor locked rotor amperes
A
49
Features
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
ON / OFF 12 hours, 1-hour OFF
Fan speeds
Indoor / Outdoor
3 and Auto / 1 (Hi)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
lb. (kg)
1.34 (0.61)
Refrigerant control
Capillary tube
Operation sound
Indoor: Hi / Me / Lo
dB-A
39 / 37 / 34
41 / 38 / 33
Outdoor: Hi
dB-A
45
43
Refrigerant tubing connections
Flare
Max allowable tubing length at shipment
ft. (m)
25 (7.5)
Refrigerant tubing 
Narrow tube
inch (mm)
1/4 (6.35)
diameter
Wide tube
inch (mm)
3/8 (9.52)
Cooling
Heating
Voltage Rating
115V