Desa SF20PT 사용자 설명서

다운로드
페이지 48
www.desatech.com
116307-01B
14
OPERATING HEATER
Continued
If pilot flame pattern is incorrect, as shown in 
Figure 19
•  turn heater off (see To Turn Off Gas to Ap-
pliance, page 13)
•  see Troubleshooting, page 16
Note: 
The pilot flame on natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 19 - Incorrect Pilot Flame Pattern
Figure 18 - Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Blue Pilot Flame
Yellow Pilot Flame
BURNER FLAME PATTERN
 WARNING: If yellow tipping 
occurs, your heater could pro-
duce increased levels of carbon 
monoxide.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dirt 
or other fine particles enter the 
heater  and  burn  causing  brief 
patches of orange flame.
THERMOSTAT CONTROL 
OPERATION
The thermostatic control used on these models 
differs from standard thermostats. Standard 
thermostats simply turn on and off the burner. 
The thermostat used on this heater senses the 
room  temperature. At  times  the  room  may 
exceed the set temperature. If so, the burner 
will shut off. The burner will cycle back on 
when room temperature drops below the set 
temperature. The control knob can be set to 
any heat level between 1 and 5. 
T
his adjusts the 
amount of gas flow to the burner that increases 
or decreases the burner flame height.
Note:
 
The thermostat sensing bulb measures 
the temperature of air near the heater cabinet. 
This may not always agree with room tem-
perature (depending on housing construction, 
installation location, room size, open air tem-
peratures, etc.) Frequent use of your heater will 
let you determine your own comfort levels.
MANUAL LIGHTING 
PROCEDURE
1.  Remove front panel (see Figure 10, page 9).
2.  Follow steps 1 through 7 under Lighting 
Instructions, page 13.
3.  With control knob pressed in, strike match. 
Hold match to pilot until pilot lights. 
4.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control  knob.  Now  follow  step  9,  under 
Lighting Instructions, page 13.
5.  Replace front panel.
INSPECTING HEATER
Check pilot flame pattern and burner flame pat-
tern often.
PILOT FLAME PATTERN
Figure 18 shows a correct pilot flame pattern. Figure 
19 shows an incorrect pilot flame pattern. The incor-
rect pilot flame is not touching the thermocouple. 
This will cause the thermocouple to cool. When the 
thermocouple cools, the heater will shut down.