PRESSURE TESTING HEATER GAS 
CONNECTIONS
1.  Open equipment shutoff valve (see Figure 16, 
page 13).
2.  For natural gas open main gas valve located 
on or near gas meter. For propane/LP gas open 
propane/LP supply tank valve.
3.  Make sure control knob of heater is in the OFF 
position.
4.  Check all joints from equipment shutoff valve 
to thermostat gas valve (see Figure 17 or 18). 
Apply a noncorrosive leak detection fluid to 
all joints. Bubbles forming show a leak.
5.  Correct all leaks at once.
6.  Light heater (see Operating Heater, page 14). 
Check all other internal joints for leaks.
7.  Turn off heater (see To Turn Off Gas to Appli-
ance, page 15).
8.  Replace front panel.
INSTALLATION
Continued
Figure 18 - Checking Gas Joints for 
Propane/LP Gas
Equipment 
Shutoff Valve
Propane/LP 
Supply Tank
Thermostat Gas Valve
Figure 17 - Checking Gas Joints for 
Natural Gas
Equipment 
Shutoff Valve
Gas 
Meter
Thermostat Gas Valve
OPERATING HEATER
FOR YOUR SAFETY  
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must be 
lighted by hand. When lighting the pilot, 
follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than 
air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not 
use any phone in your building.
• Immediately call your gas supplier from 
a  neighborʼs  phone.  Follow  the  gas 
supplierʼs instructions.
• If you cannot reach your gas supplier, call 
the fire department.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. If the 
knob will not push in or turn by hand, donʼt 
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted 
repair may result in a fire or explosion.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately  call  a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water.
LIGHTING 
INSTRUCTIONS
1.  STOP!  Read  the  safety  information 
above.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Turn control knob clockwise 
 to the 
OFF position.
4.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety information above. If you donʼt smell 
gas, go to the next step.