3. Repeat for each inspection slot.
To adjust:
1. If necessary, loosen gap adjustment nuts until a 
.005" feeler gauge fits between armature and 
rotor.
2. Slide a .012" feeler gauge between armature and 
rotor.
3. Tighten gap adjustment nut until there is slight 
contact on feeler gauge.
4. Repeat steps 1 – 3 at each inspection slot.
NOTE: Adjust air gap as evenly as possible.
5. Start unit, engage and disengage PTO.
6. Shut off unit.
7. Recheck air gap and adjust if needed.
BATTERY (988104)
Unit comes equipped with a maintenance-free battery 
that requires no regular maintenance except cleaning 
the terminals. See Check Battery (988104) on page 18.
Charge Battery
Battery Electrolyte First Aid
External Contact: Flush with water.
Eyes: Flush with water for at least 15 minutes 
and get medical attention immediately!
Internal Contact: Drink large quantities of water. 
Follow with Milk of Magnesia, beaten egg or 
vegetable oil. Get medical attention immediately! 
DO NOT induce vomiting!
IMPORTANT: DO NOT fast charge. Charging at a 
higher rate will damage or destroy battery.
IMPORTANT: ONLY use an automatic charger 
designed for use with your battery. ALWAYS follow 
information provided on battery and battery charger. 
Contact battery and charger manufacturers for detailed 
instructions.
1. Remove battery cover.
2. Disconnect negative (–) cable first, then positive 
3.  Remove battery.
4. Place battery on bench or other well-ventilated 
area.
5. Connect positive (+) lead of charger to 
positive (+) terminal, and negative (–) lead to 
negative (–) terminal.
6. Charge battery according to charger and battery 
manufacturers’ instructions.
7. Reinstall battery on unit and connect positive (+) 
cable first, then negative (–) cable.
It may be possible to recharge the battery by jump 
starting the unit and allowing the engine to run.
Jump Start
The unit used for jump starting should have a 12-volt 
battery with at least 500 cold cranking amperes, and a 
negatively grounded system.
1. Ensure battery is not frozen. If the fluid is frozen, 
remove battery from unit and allow it to thaw 
before charging.
2. Connect the positive (+) jumper cable to the 
positive terminal of the discharged battery.
3. Connect the other end of the same jumper cable 
to the positive (+) terminal of the booster battery.
4. Connect one end of the second jumper cable to 
the negative (–) terminal of the booster battery.
WARNING: AVOID INJURY. Read and 
understand the entire Safety section before 
proceeding.
WARNING: FROZEN BATTERIES CAN 
EXPLODE
 and result in death or serious 
injury.
DO NOT charge a frozen battery. Let the 
battery thaw before charging.
1
2
3
4
1. Armature
2. Rotor
3. Inspection Slot
4. Gap Adjustment 
Nut
4
Figure 14
OG1500
1. Positive terminal
2. Negative terminal
3. Battery
2
1
3
OF1670
Figure 15