Vermont Casting SDDVRBD 사용자 설명서

다운로드
페이지 52
27
Stardance Direct Vent - Rear Vent Gas Heaters 
20012950
seated. Depress lock tab to secure the cap to the pipe. 
NOTE: In high wind areas, it is recommended to screw 
termination to the pipe with two (2) #8 x 1/4” sheet 
metal screws. The screws should be approximately 3/4” 
from the bottom of the vertical termination’s galvanized 
collar.
Connect the Gas Supply Line
Check the rating plate attached by a steel cable to the 
firebox, to confirm that you have the appropriate firebox 
for the type of fuel to be used. The Stardance may be 
converted from one gas to another using the appropri-
ate Fuel Conversion Kit listed on Page 47.
This appliance should only be connect-
ed by a qualified gas technician. Test to 
confirm manifold pressures as specified 
below.
The Stardance Heaters and the individual shut-
off valves must be disconnected from the gas 
supply piping during any pressure testing of that 
system at test pressures in excess of 1/2 psig 
(3.5 kPa).
The Stardance Heaters must be isolated from the 
gas supply piping system by closing the indi-
vidual manual shutoff valve during any pressure 
testing of the gas supply piping system at test 
pressure equal to or less than 1/2 psig.
There must be a gas shutoff between the stove 
and the supply.
In order to connect Natural Gas, use a fitting 
with 3/8” NPT nipple on the valve side and 1/2” 
natural gas supply line with a minimum input 
of 21,000 BTUs at a minimum inlet supply for 
adjustment of 5.5” w.c. 
In order to connect Propane, use a fitting with 
3/8” NPT nipple on the valve side and 1/2” pro-
pane gas supply line with a minimum input of 
21,000 BTUs at a and minimum inlet pressure of 
11.0” w.c.
CAUTION
In the U.S.: Gas connection should be made in ac-
cordance with current National Fuel Gas Code, ANSI 
Z223.1/NFPA 54. Since some municipalities have 
additional local codes, be sure to consult your local 
authority.
In Canada: consult the local authority and CSA-B149.1 
installation code.
Connect the gas supply and test for leaks. Use a mild 
soap and water solution applied with a brush no larger 
than 1” (25 mm). Never apply soap and water solution 
with a spray bottle. Do not use an open flame for leak 
testing.
Burner Information
The appliance must only use the gas specified on the 
rating plate, unless converted using a Vermont Castings 
Fuel Conversion Kit. Refer to Page 47 for correct Fuel 
Conversion Kit for your stove model.
Coversion instructions are provided with each kit and 
beginning on Page 39 of this manual.
THIS APPLIANCE SHOULD BE CONNECTED TO 
THE GAS SUPPLY ONLY BY A QUALIFIED GAS 
SERVICE TECHNICIAN. FOLLOW ALL LOCAL 
CODES.
THERE MUST BE A GAS SHUT-OFF BETWEEN 
THE STOVE AND THE SUPPLY.
Complete the Assembly
•  Open the swiveling latches (cams) on the top left 
and right corners of the glass frame.
•  Position the glass and frame against the firebox by 
placing the bottom edge on the brackets on the bot-
tom face of the firebox.
•  Swing the assembly against the firebox, and close 
the latches firmly against the pins protruding from 
the firebox top.
Install ON/OFF Switch
The switch assembly parts are found in the parts bag.
1.  Attach switch assembly to left rear side of stove 
shroud using two screws and existing holes in 
shroud. (Fig. 48)
2.  Run wires down back of stove, under bottom of rear 
shroud to valve.
3.  Attach wires to valve terminals. (Fig. 49)
ST315
attach switch assy
1/31/00   djt
Switch As-
sembly
Screws
Existing 
Holes
ST315
Fig. 48  Attach switch assembly to rear shroud.