Vermont Casting SDDVRBD 사용자 설명서

다운로드
페이지 52
33
Stardance Direct Vent - Rear Vent Gas Heaters 
20012950
3.  Open control access panel.
4.  Push in gas control knob slightly and turn clock-
wise 
  to “OFF”.  Do not force.
5.  Close control access panel.
1.  STOP!  Read the safety information above.
2.  Turn off all electrical power to the fireplace.
3.  Turn the On/Off switch to “OFF” position, set 
the remote to OFF or set thermostat to lowest 
level.
4.  Open control access panel.
5.  Push in gas control knob slightly and turn 
clockwise 
 to “OFF”.
10. Push the control knob all the way in and hold.  
Immediately light the pilot by repeatedly depress-
ing the piezo spark ignitor until a flame appears. 
Continue to hold the control knob in for about one 
(1) minute after the pilot is lit. Release knob and it 
will pop back up. Pilot should remain lit. If it goes 
out, repeat steps 5 through 8.
FOR YOUR SAFETY READ BEFORE LIGHTING
•  If you cannot reach your gas supplier, call the 
Fire Department
C. Use only your hand to push in or turn the gas 
control knob. Never use tools. If the knob will not 
push in or turn by hand, do not try to repair it, call a 
qualified service technician. Applying force or any 
attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under 
water.  Immediately call a qualified service techni-
cian to inspect the heater and to replace any part of 
the control system and any gas control which has 
been under water.
A.  This heater has a pilot which must be lit manu-
ally.         When lighting the pilot follow these 
instructions exactly.
B.  BEFORE LIGHTING smell all around the heater 
area for gas. Be sure to smell next to the floor 
because some gas is heavier than air and will 
settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any fireplace
•  Do not touch any electric switch
•  Do not use any phone in your building
•  Immediately call your gas supplier from a neigh-
bor’s phone.  Follow the gas supplier’s instruc-
tions.
To Turn Off Gas To Heater
Lighting And Operating Instructions
1.  Turn the On/Off switch to Off position or set the 
thermostat to lowest setting.
2.  Turn off all electric power to the  fireplace if 
service is to be performed.
Lighting Instructions
6.  Remove glass door before lighting pilot. (See 
Glass Frame Removal section).
7.  Wait five (5) minutes to clear out any gas. Then 
smell for gas, including near the floor. If you 
smell gas, STOP!  Follow “B” in the safety infor-
mation above. If you do not smell gas, go to the 
next step.
8.  Visibly locate pilot by the main burner.
9.  Turn knob on gas control counterclockwise 
 to “PILOT”.
  •    If knob does not pop up when released, stop 
and immediately call your service technician or 
gas supplier.
  •    If after several tries, the pilot will not stay lit, 
turn the gas control knob to “OFF” and call your 
service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. Turn the On/Off switch to “ON” position or set 
thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
WARNING:If you do not follow these instructions exactly, a fire or explosion 
may result causing property damage, personal injury or loss of life.
Euro SIT
SIT NOVA
Honeywell
�����
��
���
��
PILOT 
O
FF
 
OFF
 
FP1067
lighting instruction
knobs
3/9/01   djt
5
4
3
2
1
OF
F
Pi
lo
t
3/8" - 1/2"
FP1068
Lighting instructions
Pilots