Stardance Direct Vent - Rear Vent Gas Heaters 
20012950
ST128a
SDVR
flue centerline
10/9/00  djt
C
L
18���"
(476mm)
2���"
(63mm)
"
(102 mm)
"
(102 mm)
ST128a
Parallel Installation: Minimum Clearance 
and Flue Centerline
Fig. 3  Parallel installation, minimum back and side clearance.
ST129a
stardance
corner specs
10/9/00   djt
Max. Vent 
Length
20" (508mm)
7¹⁄₂"
(190mm)
2" (50mm)
2" 
(50mm)
ST129a
Corner Installation: Minimum Clearance 
and Flue Centerline
Fig. 4  Corner installation, minimum corner clearance and flue 
centerline.
ST381a
SDVR 
clearance diagram
10/9/00   djt
9"
(230mm)
Max. Mantel
Width
See 
Fig. 6
6"
(150mm)
Sidewall/
Trim
2���"
(63mm)
Rear Wall
ST381a
Wall and Ceiling Clearances
Fig. 5  Clearances to ceiling or alcoves.
Mantel Clearances
Noncombustible 
Materials
ST382
Pinnacle
mantel clearances
6/13/00   djt
A
B
3" (75mm) Min.
ST382
A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater
 
A (Max.) 
 
B (Min.)
 
9”  
 
10¹⁄₂” 
 
 
(230 mm) 
 
(270 mm) 
 
7¹⁄₂” 
 
9” 
 
 
(190 mm) 
 
(230 mm) 
 
6” 
 
7¹⁄₂” 
 
 
(152 mm) 
 
(190 mm) 
 
4¹⁄₂” 
 
6” 
 
 
(114 mm) 
 
(152 mm) 
 
3” 
 
4¹⁄₂” 
 
 
(76 mm) 
 
(114 mm) 
 
1¹⁄₂” 
 
3” 
 
 
(38 mm) 
 
(76 mm)
Fig. 6  Mantel / top trim clearances.
Combustible 
Mantel or Trim 
Materials
Hearth Requirements 
The Stardance Heater must be installed on rigid floor-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or 
wood panel extending the full width and depth of the 
unit must be used as the hearth. There are no other 
hearth requirements.