Marantz PD4201 사용자 설명서
PDxx01
RS-232C Control Specification Page: 11 / 49
Document Version [1.0]
Company Restricted
5-9.
SHARPNESS Gain Data
Function
The external control equipment changes the SHARPNESS gain data of the plasma monitor.
Transmission Data
The external control equipment changes the SHARPNESS gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: SHARPNESS Gain Flag
06H
DATA02: SHARPNESS Gain
F0H: -16
:
FFH:
-01
00H:
0
01H:
+01
:
10H:
+16
Only when a RGB signal is connected
DATA02 : SHARPNESS Gain
01H: 1
02H:
2
03H:
3
04H:
4
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: SHARPNESS Gain Flag
06H
5-10.
COLOR Gain Data
Function
The external control equipment changes the COLOR gain data of the plasma monitor.
Transmission Data
The external control equipment changes the COLOR gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: COLOR Gain Flag
04H
DATA02: COLOR Gain
E0H: -32
:
FFH:
-01
00H:
0
01H:
+01
:
20H:
+32
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: COLOR Gain Flag
04H