40
CLI: diagnostics
PowerAudibleAlarm
Silences the audible alarm for a current power supply 
failure. The alarm will be activated on the next power 
failure.
Immediate command: PowerAudibleAlarm disabled
RAID5ClearDataStatus
Displays the status of RAID5 Clear Data processing. S 
represents the sled number, D represents the drive 
number. Applies to RAID5 only
Set syntax: RAID5ClearDataStatus
RAIDRebuildStatus
Displays the RAID1, RAID 5 or RAID 10 Rebuild Status 
Summary. If no RAID groups are defined, the header 
information is displayed with no data. The status 
summary contains the RAID1, RAID 5 or RAID 10.The 
RAIDRebuildStatus command has no effect on the state 
of any rebuild in progress.
Member index and the following fields in tabular form:
• 
S t a t u s
: OK, DEGRADED, IN PROGRESS, or 
FAULTED
• 
S l e d   N u mb e r
: Location of the sled 
• 
C u r r e n t   L B A
:  Logical block currently being 
rebuilt
• 
M a x i m u m  L B A :
  Last logical block to be 
rebuilt
• 
S t a t u s   O K
: the RAID1 Mirror is in sync and no 
rebuild activity is occurring. The Current LBA, 
Maximum LBA and percentage complete values 
are not displayed.
• 
S t a t u s   D e g r a d e d
: the RAID1 Mirror is out of 
sync and is waiting to be rebuilt.
• 
S t a t u s   I n   P r o g r e s s
: the RAID1 Mirror is out of 
sync and a rebuild is occurring on the respective 
drive.
• 
S t a t u s   F a u l t ed
: the RAID1 Mirror is out of sync 
and an error occurred in an attempt to 
synchronize the drives in the RAID 1 group.
SerialNumber
View the board serial number, a 10-character field. The 
first four alphanumeric characters are an abbreviation 
representing the product name. The remaining six digits 
are the individual unit’s number.
Get syntax: get SerialNumber
SledFaultLED
Changes the state of the selected sled LED to the 
indicated state. Choose the sled number, 
1-12, 
or 
all
, turn 
on
 or 
off
Default: off
Set syntax: set SledFaultLED [ all | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 
8 | 9 |10 |11| 12] [ on | off]
SMARTData
Displays the current SMART (Self-Monitoring Analysis 
and Reporting Technology) data for the specified drive.
Immediate command: SMARTData [sled#] [drive #]
TapeDriveInfo
Displays information about the named Tape Drive 
including LUN, Tape Volume ID and state of the tape 
drive.
Get syntax: TapeDriveInfo [tape drive #]
TapeVolumeInfo
Displays information about the named Tape Volume 
including Volume ID, LUN, Virtual Disk ID, Partition ID, 
Total capacity and percentage of capacity used.
Get syntax: TapeVolumeInfo [tape volume #]
Temperature
Returns the current internal temperature of this Diamond 
Storage Array in degrees Celsius. The value is read only.
Get syntax: get Temperature
VirtualDriveInfo
Displays the named Virtual Drive definitions.
Get syntax: VirtualDriveInfo [active|planned] [Virtual 
Drive ID]
ZoneInfo
Displays the named zones’ definitions. Information about 
the Active Zone Configuration is the default; if you want 
information about the Planned Zone Configuration, type 
ZoneInfo Planned zone_name.
Zone syntax: ZoneInfo [Planned] [zone_name] [all] 
ZoneState
Changes the specific state of a zone. The ZoneState 
command must be entered as enabled to activate the zone 
before using the ZoneCommit command (which makes 
the Planned Zone Configuration the Active 
configuration). 
Default: disabled
Set syntax: ZoneState zone_name [enabled|disabled]
Get syntax: ZoneInfo