ATTO Technology diamond array vt 사용자 설명서

다운로드
페이지 96
63
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
9.2  Resetting Defaults
Resetting the Diamond-VT to defaults will not alter the RAID configuration, zoning configuration, IP 
configuration or Telnet information. However, resetting the Diamond-VT to factory defaults is a last-ditch effort 
to recover from corrupt configurations or complete failure. All data will be lost, but the zoning configuration will 
remain. 
CAUTION
CAUTION
Data will be lost if you follow these 
procedures. Make sure you have no other 
choice before resetting the Diamond-VT to 
factory defaults.
Default
If you need to return to the default settings of the 
Diamond-VT but do not want to lose data or Ethernet 
settings, use the CLI command 
RestoreConfiguration 
default
 in CLI mode or in the Advanced CLI 
configuration page of the ExpressNAV interface.
Note
Using 
RestoreConfiguration default
 or 
RestoreConfiguration factory default 
will not 
affect the zoning configuration. To restore the 
Diamond-VT to factory default, type 
ZoneClearAll 
ZoneCommit
Return to Default settings
1
Connect to Diamond-VT services via the RS-232 
port or the optional Ethernet management 
services card (see 
Accessing the Diamond-VT 
on 
page 15). You should now be in Command Line 
Interface. Continue with the CLI or access the 
ExpressNAV interface (see 
ATTO ExpressNAV: 
Browser-based Interface 
on page 23). 
Note
Because the ExpressNAV pages take you 
through this process easily, the following 
instructions are based on the CLI commands. 
Use these instructions as a guide in ExpressNAV.
2
Type 
RestoreConfiguration default
 to reset the 
system configuration (See Exhibit 9.2-2 for a list of 
configurations which will be changed).
3
Type
 FirmwareRestart
 or cycle power of the 
Diamond-VT.
4
Reboot the host PC after the Diamond-VT 
completes its power on cycle.
Factory Default
Resetting the Diamond-VT to factory defaults is a last-
ditch effort to recover from corrupt configurations or 
complete failure. All data will be lost.
Note
Using 
RestoreConfiguration default
 or 
RestoreConfiguration factory default 
will not 
affect the zoning configuration. To restore the 
Diamond-VT to factory default, type 
ZoneClearAll 
ZoneCommit
To reset to Factory Defaults, firmware version 
2.5.3 or higher
1
Connect to Diamond-VT services via the RS-232 
port or the optional Ethernet management 
services card (see 
Accessing the Diamond-VT 
on 
page 15). You should now be in Command Line 
Interface. 
2
Continue with the CLI or access the ExpressNAV 
interface (see 
ATTO ExpressNAV: Browser-based 
Interface 
on page 23). 
Note
Because the ExpressNAV pages take you 
through this process easily, the following 
instructions are based on the CLI commands. 
Use these instructions as a guide in ExpressNAV.
3
Type 
RestoreConfiguration factorydefault
 to reset 
the system configuration. (See Exhibit 9.2-2 for a 
list of configurations which will be changed).
4
Type 
FirmwareRestart
 or cycle the Diamond-VT 
power.
5
Reboot the host PC after the Diamond-VT 
completes its power on cycle.