Bosch ltc-0335-28 설치 설명서

다운로드
페이지 188
60
en | Configuring events and alarms
Bosch Video Management System
Configuration Client | V3 | 2010.07
Configuration Manual
Bosch Sicherheitssysteme GmbH
3.
Click .
A new table row is added below.
It has the default settings.
11.6
Logging user events
Main window > 
 Events > Expand System Devices > User Actions
You can configure the logging behavior of several user actions for each availabluser group 
individually.
Example:
To log user events:
1.
Select a user event to configure its logging behavior, e.g. Operator Logon.
The corresponding Event Configuration Table is displayed. 
Each user group is displayed in the Device column.
2.
If available: In the Trigger Alarm - Schedule column, click a cell and select the 
appropriate schedule.
The schedule determines when the alarm that is supposed to notify the user is triggered. 
in Schedules.
3.
In the Log - Schedule column, click a cell and select the appropriate schedule. 
The schedule determines when the event is logged.
In the example, the Operator logon of the Admin Group and the Power User Group are 
not logged whereas the Operator logon of the Live User Group are logged during Day 
schedule. During the selected schedule, each Operator logon is displayed in the Event 
List of each user of the Live User group.
4.
In the Minimum Event Time column, click a cell and type the number of milliseconds as 
the minimum time period that the event must last to be a single event.
The following screenshot displays this example:
11.7
Configuring user event buttons
Main window > 
 Events
You can configure the user event buttons available in the Operator Client. You can configure 
that one or more user event buttons are not displayed in the Operator Client.
On the User Groups page, you configure that the user event buttons are only available in the 
Operator Client of the corresponding user group.