Datamax m-class mark ii 사용자 가이드

다운로드
페이지 100
 
Chapter 4 – Menu System 
27 
 
SENSOR 
CALIBRATION 
Selects the media sensor calibration method, where: 
PERFORM 
CALIBRATION 
Sets the values via internal printer calculations, as described in the STANDARD 
CALIBRATION procedure. 
ADVANCED ENTRY 
Sets the values via manual entry (typically for hard to calibrate label stocks), as 
described in the ADVANCED ENTRY CALIBRATION where:  
PAPER SENSOR 
LEVEL 
Establishes the threshold for the paper value (0 - 255), where 170 is the default 
setting. 
REFL PAPER 
LEVEL 
Establishes the threshold for the reflective value (0 - 255), where 170 is the 
default setting. 
GAP SENSOR 
LEVEL 
Establishes the threshold for the gap value (0 - 255), where 040 is the default 
setting. 
MARK SENSOR 
LEVEL 
Establishes the threshold for the mark value (0 - 255), where 040 is the default 
setting. 
EMPTY SENSOR 
LEVEL 
Establishes the threshold for the empty value (0 - 255), where 000 is the default 
setting. 
TRAN SENSOR 
GAIN 
Establishes the sensitivity of the transmissive sensor (0 - 31), where 15 is the 
default setting.  
REFL SENSOR 
GAIN 
Establishes the sensitivity of the reflective sensor (0 - 31), where 15 is the 
default setting. 
PRINTHEAD 
CLEANING 
Controls the automatic cleaning alert and function, where:  
CLEAN HEAD 
SCHEDULE 
Specifies the inch (or centimeter) count at which to clean the printhead, and if 
exceeded three times, declare a Head Cleaning Fault.  (Note that the specified 
count [0 - 200 inches] will be multiplied by one thousand, and that zero [the 
default setting] will disable the function.)   
CLEAN HEAD 
COUNTER 
Indicates the number of inches (or centimeters) since a cleaning was last 
initiated. 
RESET COUNTER 
Resets the Clean Head Counter to zero to restart the Clean Head Schedule. 
CLEAN HEAD NOW 
Initiates the cleaning process and resets the Clean Head Counter.