Chapter 4 – Menu System 
45 
Diagnostics 
The Diagnostics menu contains testing functions and printhead reporting selections: 
 
 
Hex Dump Mode 
 
Options Testing 
 
Print Test Rate (min) 
 
Sensor Readings 
 
Ribbon Sensor Limits 
 
iPH Report 
 
Icon Descriptions 
 
The menu selections are defined as follows: 
 
DISPLAYED ITEM 
ITEM DESCRIPTION 
HEX DUMP MODE 
Determines how the printer handles the data received from a host, where:   
ENABLE 
The printer outputs the raw ASCII data it receives without interpretation; no 
processing occurs. 
DISABLE 
Processes data normally. (Default Setting) 
FILE CAPTURE 
Saves the incoming data to Module H (USB thumbdrive) if present; otherwise, the 
file is stored on Module G. The file name, in the form [dmx_xxx_yyy.dpl], where 
the count is automatically incremented for every capture and a unique printer time 
stamp (xxx), is assigned.  
OPTIONS TESTING 
Performs printer option diagnostics or monitors and outputs test results, where:  
TEST PRESENT 
SENSOR 
Performs a functional test of the Present Sensor by indicating LABEL PRESENTED 
(when a label blocks the sensor) and LABEL NOT PRESENTED (when no label blocks 
the sensor). (Note that this test can also be used to check the sensor function of the 
Peel & Present option.) 
TEST CUTTER 
Performs a functional test of the Cutter, where: 
PERFORM 
TEST 
001 TIMES 
Cycles the cutter blade a selected number of times (0 - 999), with PASS / FAIL 
results given for each cycling attempt.   
TEST GPIO 
Performs a functional test of the GPIO port, where: 
MONITOR 
GPIO INPUT  
Displays input signal logic values for Start of Print (SOP). 
 
 
If unconnected, a zero or one may be displayed.  
 
TEST GPIO 
OUTPUT 
Displays output signal logic values for End of Print (EP) and Service Required (SR).    
 
 
To change an output signal state, cursor over the displayed state 
to select and then toggle it using the UP or Down Arrow Buttons.  
 
PRINT 
SIGNAL INFO  
Prints a reference label containing GPIO signal names, pin assignments, programmed 
settings, and current signal states. 
TEST RFID 
Performs a functional test of the RFID option, where: 
TAG DATA 
Reads the data encoded on the RFID chip. 
DEVICE 
VERSION 
Displays the type and version of the encoding device. 
TAG ID - HF 
ONLY 
Reads and displays the High Frequency Tag ID number.   
PRINT TEST RATE 
(MIN) 
Sets a label-to-label delay interval (0 - 120 minutes) when Test label batch printing, 
where: 
000 
Is the Default Setting.