3.7.1 Quick Calibration 
 
Quick Calibration should be performed as part of the media loading routine to fine-tune the sensing 
parameters.   
  
 
(1) This calibration is not necessary when using continuous stock. 
  
(2) Media containing large gaps may require a change in the PAPER OUT DISTANCE before proceeding. 
 
Calibrate the printer as follows: 
 
1.  Ensure that the printer is ON and in an idle state (i.e., not off-line) with media loaded, the media sensor 
adjusted, and the sensor type selected.   
 
2.  Press and hold the 
F2
 button until one label has been output then release. Wait for the printer to process 
the data. There are two possible outcomes: 
 
Upon completion, one of the following lights will flash five times to denote the result of the auto 
calibration attempt:  
 
POWER light = Successful calibration. 
 
FAULT light = Unsuccessful calibration, try again.  If the calibration continues to fail proceed to Section 
3.7.3.  
 
 
 
 
 
3.7.2 Empty Calibration 
 
Empty Calibration calibrates the printer’s media sensor to detect an ‘Out of Stock’ condition. Calibrate the 
printer as follows: 
 
1. 
Ensure that the printer is ON and in an idle state with media removed.   
 
2. 
Press and hold the 
F1
 
F2
 buttons for a few seconds.