3
Linksys One Ready Communications Solution SFE2000/
SFE2000P and SGE2000/SGE2000P
Linksys One Ready Communications Solution
RELEASE NOTES
1 February 2007
Known Restrictions and Limitations
Management & System Features
Headline
Description
Reference 
System->System 
Management->Time-
>System Time
The time zone setting is not applied after you upload the 
configuration from the TFTP server.
Recommended Workaround: After you upload the configuration 
file, change the time zone setting in the Time Zone Offset file.
66906
System -> Admin -> File 
Management -> Save 
Configuration
There may be cases where copying a running configuration file to 
a start up configuration file with saved VLAN values will issue 
an error after an upgrade.
Recommended Workaround: Verify that you are not trying to 
create the same value twice.
68698
System -> SNMP -> 
Security -> Users
Cannot add users to the SNMP via the GUI.
Recommended Workaround: Create SNMP groups before adding 
users.
68695
System->SNMP-
>Security->Communities
Deleting 3 or more SNMP communities advanced entities from 
the table may result in an error “Request Entity Too Large”.
Recommended Workaround: Delete one SNMP community 
entity at a time.
68090
Combo ports
MGBSX1(T) 100M SFP registers its speed as 1000M.
68440
Admin->Diagnostics-
>copper ports
Cable length for Fast Ethernet Copper Ports is not displayed.
69338
Admin->Diagnostics-
>copper ports
In a stacked configuration, running an optical test may result in 
traffic lost on the GE port.
Recommended Workaround: Disable STP on the port.
66147
Admin->Diagnostics-
>copper ports
After pressing the “Test” button, the “Advance” button is not 
displayed.
Recommended Workaround: After switching to another page and 
returning to this page, the cable length and the “Advance” button 
are displayed.
69344
System->System Mgmt-
>Zoom
Zoom view shows SFP ports number 1 & 2 description only. For 
SGE2000 Only.