Alcatel-Lucent 6850-48 참조 가이드
AAA Commands
OmniSwitch CLI Reference Guide
September 2009
page 58-65
user lockout-duration
Configures the length of time a user account remains locked out of the switch. At the end of this time
period, the user account is automatically unlocked.
period, the user account is automatically unlocked.
user lockout-duration minutes
Syntax Definitions
minutes
The number of minutes the user account remains locked out. The range
is 0 to 99999.
is 0 to 99999.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• This command is only available to the admin user because the admin user account is the only account
protected from any type of lockout attempt.
• Note that if the lockout duration time period is set to zero (the default), then locked user accounts are
never automatically unlocked.
• Only the admin user or a user with read/write AAA privileges can unlock a locked user account when
the lockout duration time is set to zero. An account is unlocked by changing the user password or with
the
the
• Do not configure a lockout duration time period that is less than the amount of time configured for the
observation window.
• The lockout duration time period is a global lockout setting that is applied to all passwords configured
on the switch.
• Lockout settings are saved automatically; that is, these settings do not require the
command to save user settings over a reboot.
Examples
-> user lockout-duration 60
-> user lockout-duration 0
Release History
Release 6.3.1; command was introduced.
parameter
default
minutes
0