Printronix l7032 참조 매뉴얼

다운로드
페이지 416
German Interleaved 2/5
 223
Quiet Zone
Both ends of the bar code structure have blank quiet zones. The quiet zones 
should be at least 0.25 inches wide and completely blank to ensure accurate 
reading of the start/stop codes and to prevent adjacent bar codes from 
overlapping. You are responsible for providing sufficient space on the form for 
the quiet zones.
Start/Stop Codes
Unique start and stop codes permit bidirectional scanning. Both start and stop 
codes contain bars and spaces. They are automatically produced.
Data Field
The bar code symbol uses a series of wide and narrow bars and spaces to 
represent numeric characters. The structure is 2 wide elements (bars or 
spaces) and 3 narrow elements. In the bar code, two characters are 
interleaved (paired); bars are used to represent data characters occupying 
the odd-numbered positions, and spaces are used to represent data 
characters occupying the even-numbered positions.
Readable Data
The optional readable data field provides a readable interpretation of the bar 
code data. Bar code data is printed below the horizontal bar code symbol and 
to the left of a vertical bar code symbol. The lower guard band is provided 
when the readable data field is selected.
Check Digit
The modulo-10 check digit is automatically calculated and inserted in the bar 
code symbol. The check digit provides the means to verify accurate scanning. 
German Interleaved 2/5 Command Format
NOTE: See page 164 for the IBARC, command format and definitions.
Default Ratio:
(cc) 
dir p type data (cc)G
Variable Ratio:
(cc) 
dir p [9] [:] type [ratio] data (cc)G
(cc)
Represents the Special Function Control Code 
(SFCC). Enter the specific SFCC for your VGL 
configuration.
dir
Represents the direction of the bar code. Enter B 
for horizontal bar codes; enter C for vertical bar 
codes.
p
Prints the optional readable data field. The 
readable data field is printed below a horizontal bar 
code or on the left-hand side of a vertical bar code.
Replace 
p in the bar code command with one of the 
codes listed in Table 45 to print the readable data 
field in the corresponding font with the specified 
guard band gap.