Software Upgrade Procedure
3-1
SM-10004-02
Chapter 3 
Software Upgrade Procedure
As networking technology advances, NETGEAR will release new versions of the software that 
runs the switch.  These software releases will provide new capabilities that can extend the useful 
life of your switch. This manual is updated whenever there is a change in either the first or second 
positions of the software version number. The third position in the software version number 
identifies bug fix and patch versions for which this manual is not updated. The upgrade procedure 
and the required equipment are described in this chapter.
IP address, Network Mask, and Default Gateway are not affected by upgrading the software.  
These settings will be preserved in non-volatile memory (NVRAM).
The upgrade process is accomplished by having the switch boot from a TFTP server instead of its 
own NVRAM.  To initiate this sequence, the user must set the ‘Next Boot From’ configuration 
parameter to ‘Boot from Net’, and then perform a ‘reset’. When the ‘Boot from Net’ option is set, 
the switch will start using an image residing on a TFTP server on the network. Be sure that the 
TFTP server residing on the network is accessible by the switch. Once completed, the software 
version should be verified in the System page. 
The upgrade procedure below gives the exact steps to follow when using the web interface.  The 
process is similar with either the CMI or CLI interfaces. 
1.
Go to Main Menu>Advanced>Advanced Tools>Software Upgrade.
2.
Select ‘Boot from Net’ option. 
3.
Verify information such as the IP address for the TFTP Server and the file name of the new 
software image.
4.
Save the setting in non-volatile memory.  Use the ‘Apply’ button and then the Tools> Save 
Configuration screen.  
Note: 
It is highly recommended, though not necessary, to use a RS-232 serial port 
connection to the switch during the software upgrade procedure. When using a Telnet 
Session or web interface alone, your connection to the switch will not be available until 
the switch has completed its boot up and entered the Spanning Tree forwarding mode. 
This can take up to three minutes.