Netgear GSM7212 사용자 설명서
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software
8-64
Switching Commands
December 2004, 202-10010-02
frames or priority tagged frames received on this port are
accepted and assigned the value of the Port VLAN ID for this
port. With either option, VLAN tagged frames are forwarded in
accordance to the 802.1Q VLAN specification.
accepted and assigned the value of the Port VLAN ID for this
port. With either option, VLAN tagged frames are forwarded in
accordance to the 802.1Q VLAN specification.
Ingress Filtering
May be enabled or disabled. When enabled, the frame is dis-
carded if this port is not a member of the VLAN with which this
frame is associated. In a tagged frame, the VLAN is identified by
the VLAN ID in the tag. In an untagged frame, the VLAN is the
Port VLAN ID specified for the port that received this frame.
When disabled, all frames are forwarded in accordance with the
802.1Q VLAN bridge specification. The factory default is dis-
abled.
carded if this port is not a member of the VLAN with which this
frame is associated. In a tagged frame, the VLAN is identified by
the VLAN ID in the tag. In an untagged frame, the VLAN is the
Port VLAN ID specified for the port that received this frame.
When disabled, all frames are forwarded in accordance with the
802.1Q VLAN bridge specification. The factory default is dis-
abled.
GVRP
May be enabled or disabled.
Default Priority
The 802.1p priority assigned to tagged packets arriving on the
port.
port.
shutdown
This command disables a port.
Default
Enabled
Format
shutdown
Mode
Interface Config
no shutdown
This command enables a port.
Format
no shutdown
Mode
Interface Config
shutdown all
This command disables all ports.
Default
Enabled
Format
shutdown all
Mode
Global Config