Netgear GSM7224 사용자 설명서

다운로드
페이지 228
User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 
Switching Commands
8-45
202-10009-01_060204
Mode  
Global Config
set garp timer leaveall
This command sets how frequently Leave All PDUs are generated per port. A Leave All PDU 
indicates that all registrations will be unregistered. Participants would need to rejoin in order to 
maintain registration. The value applies per port and per GARP participation. The time may range 
from 200 to 6000 (centiseconds).
Note: 
This command has an effect only when GVRP is enabled.
Default  
1000 centiseconds (10 seconds)
Format  
set garp timer leaveall <200-6000>
Mode  
Interface Config
no set garp timer leaveall
This command sets how frequently Leave All PDUs are generated per port to 1000 centiseconds 
(10 seconds).
Note: 
This command has an effect only when GVRP is enabled.
Format  
no set garp timer leaveall 
Mode  
Interface Config
set garp timer leaveall all
This command sets how frequently Leave All PDUs are generated for all ports. A Leave All PDU 
indicates that all registrations will be unregistered. Participants would need to rejoin in order to 
maintain registration. The value applies per port and per GARP participation. The time may range 
from 200 to 6000 (centiseconds).
Note: 
This command has an effect only when GVRP is enabled.
Default  1000 centiseconds (10 seconds)
Format  
set garp timer leaveall all <200-6000>
Mode  
Global Config