Netgear fr314 참조 가이드

다운로드
페이지 159
Reference Guide for the Model FR314, FR318 and FV318 Cable/DSL Firewall and VPN Routers
12-2
Troubleshooting
Test LED Stays On
When the router is turned on, the Test LED should illuminate for about 90 seconds and then turn
off. If the Test LED stays on, there is a fault within the router.
If you experience problems with the Test LED:
Turn off the router for a few seconds, and then turn it back on to see if the router recovers, and
if the LED turns off after the correct amount of time.
If the error persists, you might have a hardware problem. Contact NETGEAR technical support.
LNK/ACT LEDs Not On
If either the Local or Internet LNK/ACT LED does not light when the Ethernet connection is
made, check the following:
Make sure that the Ethernet cable connections are secure at the router and at the hub or PC.
Make sure that power is turned on to the connected hub or PC.
Be sure you are using the correct cable:
— When connecting the router’s INTERNET port to a cable or DSL modem, use the cable
that was supplied with the cable or DSL modem.
Note:
The Ethernet cable supplied by your ISP for connecting to your cable or DSL
modem may be an Ethernet crossover cable rather than a straight-through cable. It is
important to use this cable to connect the modem to your router, not to connect your PCs
to your router.
— If you are connecting one of the router’s LOCAL ports to a PC, use a standard
straight-through Ethernet cable like the one provided with your router.
— (FR314 only) If you are connecting the FR314’s LOCAL port 4 to a PC, set the
NORMAL/UPLINK switch to the NORMAL position.
— (FR314 only) If you are connecting the FR314’s LOCAL port 4 to another hub or switch,
set the router’s NORMAL/UPLINK switch to the UPLINK position unless you are
connecting to the other hub’s UPLINK port.