Use MIDI functionality
 
 
Sys Ex. ASSIGN
 
Here’s how you can assign a system exclusive message to a controller. Advanced mode 2 lets 
you assign a single-byte system message (System realtime message, tune request). 
Advanced modes 3 and 4 let you assign any desired message. (Input up to 24 bytes)
Sys Ex. ASSIGN can calculate the checksum automatically, and lets you specify a variable (data) 
range or embed a channel/block number within the message. (
 
 
In Sys Ex. ASSIGN, the input mode will be HEX mode.
 
fig.edt2
 
1
 
Press the 
 
[EDIT]
 
 button.
The display will indicate “EDT”.
 
fig.r-1
 
2
 
Slightly move the controller to which you want to assign the system exclusive 
message. In the case of a button, press that button.
The display will indicate the number of the selected controller.
 
3
 
Confirm what’s indicated, and press the 
 
[ENTER]
 
 button.
 
fig.se0
 
4
 
Press an 
 
ASSIGNABLE FUNCTION
 
 key (
)  on the keyboard enough times 
to get "SE0" to appear in the display. 
 
5
 
If you want to select an Advanced mode, press a key from 
 
[1]
 
 to 
 
[4]
 
.
The selected mode will blink in the display.
 
6
 
Confirm what’s indicated, and press the 
 
[ENTER]
 
 button.
 
 
 
Mode 
Key-
board
Mode
Value range
Required ending
Notes/restrictions
 
Basic mode
0
Sys Ex. message Default range
Input F7
1st byte fixed at F0
Advanced mode 1
1
Sys Ex. message Assignable
Input F7
1st byte fixed at F0
Advanced mode 2
2
Single byte sys-
tem message
 
[0–5, 7, 9, D, E]
 
 
 
[DA-
TA][CHECKSUM] 
 
but-
tons are invalid
Advanced mode 3
3
Any desired 
MIDI message
Default range
Specified number of bytes
 
[CHECKSUM] 
 
button is 
invalid
Advanced mode 4
4
Any desired 
MIDI message
Assignable
Specified number of bytes
 
[CHECKSUM] 
 
button is 
invalid
PCR-1_e.book 77 ページ 2004年3月16日 火曜日 午後2時55分