16
CLR2160, CLRCO2175
Figure 25
Leveling
IMPORTANT
IMPORTANT
It is extremely important that Clear Ice models are
level. If not level, the ice mold will not fill evenly.
level. If not level, the ice mold will not fill evenly.
Figure 26
A unit that is not level can cause a reduction in ice rate,
uneven sized cubes or water spilling into the storage area,
which will cause the ice in the bin to melt prematurely
(Figure 26).
uneven sized cubes or water spilling into the storage area,
which will cause the ice in the bin to melt prematurely
(Figure 26).
When checking the level, remember that floors near
drains have a tendency to slope towards the drain.
drains have a tendency to slope towards the drain.
Figure 27
Use a level to check the levelness of the unit from front to
back and from side to side. Level should be placed along
top edge and side edge as shown (Figure 27).
back and from side to side. Level should be placed along
top edge and side edge as shown (Figure 27).
Figure 28
5. If the unit is not level, adjust the feet on the corners of
the unit as necessary (Figure 28).
6. Check the levelness after each adjustment and repeat
the previous steps until the unit is level.
GOOD
BRIDGE
TOO THIN
BRIDGE
TOO THICK
DIMPLE
TOO DEEP
LITTLE OR
NO DIMPLE
1/4" TO 1/2"
DIMPLE
1/16" TO 1/8"
ICE BRIDGE
BAD
ULIN_0300_A
Cube Types
ULIN_0047_A
Place
level
here
level
here
ULIN_0043_A
Adjustable foot
ULIN_0044_A