The MIM-4000F is a four-port fiber gigabit Ethernet interface connecting directly to 
the gigabit Ethernet switch in the BSX8000-5 uplink module.
MIM-2E1 or MIM-4E1
Plug your E1 cable into one of the RJ45 E1 ports on the MIM faceplate. The 
MIM-2E1 or MIM-4E1 connects to an E1 network extender provider unit, or an 
interface module in another BLC, via a standard E1 line.
Verify the connection: the Lnk (link) LED on the MIM faceplate flashes green to 
indicate a network connection has been established.
MIM-2T1 or MIM-4T1
Plug your T1 cable into one of the RJ45 T1 ports on the MIM faceplate. The 
MIM-2T1 or MIM-4T1 connects to a T1 network extender provider unit, or an 
interface module in another BLC, via a standard T1 line.
Verify the connection: the Lnk (link) LED on the MIM faceplate flashes green to 
indicate a network connection has been established.
BLC Management
The BSX8000-5 uplink module provides BLC management capability via the  
Command Line Interface (CLI), Simple Network Management Protocol (SNMP), 
and the web-based Network Management System (NMS). 
Web Interface (NMS)
The following are required for use of the NMS:
„
Web Browser – Required for running NMS. Compatible web browsers 
include, but are not limited to, Microsoft Internet Explorer (version 6.0 or 
higher) and Netscape Navigator (version 6.0 or higher). NMS is optimized for 
use with Internet Explorer. 
„
Use your browser's default settings when running NMS. JavaScript must be 
enabled.
„
Screen Resolution – 1024 x 768 pixels is the minimum resolution required for 
all NMS views to fit within the dimensions of most monitors and laptops. Lower 
screen resolutions (such as 800 x 600 pixels) may cause NMS screens to 
exceed the width or height of the screen. To verify screen resolution on a 
Windows system:
— Right click on your desktop
— Select Properties
— Click the Settings tab
— Adjust the Screen Resolution as needed