Milan mil-sm4804g 사용자 설명서

다운로드
페이지 68
Connectivity Rules
4-5
4
3.
Connect one end of the cable to the LC port on the switch and the other end to 
the LC port on the other device. Since LC connectors are keyed, the cable can 
be attached in only one orientation.
Figure 4-3  Making Fiber Port Connections
4.
As a connection is made, check the Link LED on the switch corresponding to 
the port to be sure that the connection is valid.
The 1000BASE-SX, 1000BASE-LX, 1000BASE-LH fiber optic ports operate at 
1 Gbps, full duplex, with auto-negotiation of flow control. The maximum length for 
fiber optic cable operating at Gigabit speed will depend on the fiber type as listed 
under “1000 Mbps Gigabit Ethernet Collision Domain” on page 4-6. 
Connectivity Rules
When adding hubs (repeaters) to your network, please follow the connectivity rules 
listed in the manuals for these products. However, note that because switches break 
up the path for connected devices into separate collision domains, you should not 
include the switch or connected cabling in your calculations for cascade length 
involving other devices. 
1000BASE-T Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections should also 
work for 1000BASE-T, providing that all four wire pairs are connected. However, it is 
recommended that for all critical connections, or any new cable installations, 
Category 5e (enhanced Category 5) or Category 6 cable should be used. The 
Category 5e and 6 specifications include test parameters that are only 
recommendations for Category 5. Therefore, the first step in preparing existing 
46