GMX 200 Environmental Qualification Form 
005-00315-20 
Page 2 of 2 
  Rev 1 
Operational Shocks & Crash Safety 
 
Sustained Crash Safety 
7.0 
 
7.3.2 
 
Equipment tested to Category B 
 
Equipment tested for Random Orientation. [B5R] 
Vibration 8.0 
 
Equipment tested to Category S,  
                    Test Curves B & M  
 
Note: Vibration Test Curve M was increased to DO-160C 
Helicopter Test Curve N as follows:  0.1 inches pk-
pk double amplitude from 5Hz to 17Hz and 1.5g pk 
from 17Hz to 500Hz. 
 
Explosion Proofness 
9.0 
 
Equipment identified as Category X, no test performed 
Waterproofness 10.0 
 
Equipment identified as Category X, no test performed 
Fluids Susceptibility 
11.0 
 
Equipment identified as Category X, no test performed 
Sand and Dust 
12.0 
 
Equipment identified as Category X, no test performed 
Fungus Resistance 
13.0 
 
Equipment identified as Category X, no test performed 
Salt Spray 
14.0 
 
Equipment identified as Category X, no test performed 
Magnetic Effect 
15.0 
 
Equipment tested to Category Z 
Power Input 
 
16.0 
Equipment tested to Categories A & B  
 
Voltage Spike 
17.0 
 
Equipment tested to Category A 
Audio Frequency Conducted 
Susceptibility  
18.0 
 
Equipment tested to Category Z 
Induced Signal Susceptibility 
19.0 
 
Equipment tested to Category C 
Radio Frequency Susceptibility 
 
20.0 
 
Equipment tested to Category VV- 
 
Emission of Radio Frequency 
Energy 
21.0 
 
Equipment tested to Category M 
Lightning Induced Transient 
Susceptibility 
22.0 
 
Equipment tested to Category A3E3 
Lightning Direct Effects 
23.0 
 
Equipment identified as Category X, no test performed 
Icing 24.0 
 
Equipment identified as Category X, no test performed 
Electrostatic Discharge (ESD) 
25.0 
 
Equipment identified as Category A 
AS8034 Thermal Shock 
 
5.23 
SAE document – AS8034 
Notes and Remarks: 
1.  Test Information can be found in Garmin document 005-00315-19.