Hussmann c5x-lep 데이터 시트

다운로드
페이지 8
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H. 
C5X-LEP
D
AIRY
/D
ELI
/P
RODUCE
U
NLIT
L
IT
Discharge Air (°F)
33
31
Evaporator (°F)
28
26
Unit Sizing (°F) 
26
24
For red meat application, lower evaporator
temperature and unit sizing 3°F. increase Btu 5%.
Btu/hr/ft — Unlit Shelves
C5X-LEP
‡‡
Parallel
Conventional
U
NLIT
1420
1490
‡‡ Add 10 Btu/hr/ft per shelf row for LED fixtures.
Add 20 Btu/hr/ft per shelf row for fluorescent lamps.
DEFROST DATA
C5X-LEP
Frequency Hrs
12
Defrost Water (lb/ft/day)
10.5
(± 15% based on case configuration and product
loading).
O
FFTIME
C5X-LEP
TIME (minutes)
30
E
LECTRIC OR
G
AS
Not Recommended 
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO*
C5X-LEP
D
AIRY
/D
ELI
/P
RODUCE
††
Temp (°F)                        19°F / 9°F
Indoor Unit Only, Pressure Defrost
Termination*
48°F
*Use a Temperature Pressure Chart to determine
PSIG conversions.
††For red meat application, reduce low pressure
backup control by 3°F. 
Estimated Charge (lb)**
C5X-LEP
4 ft
1.9
6 ft
2.6
8 ft
3.7
12 ft
5.1
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by approxi-
mately half a pound.
3 of 8
P/N 0479715_B
HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM
31 
5
/
(804)
3
/
(120)
30 
1
/
4   
(768)
42
 
(1064)
33 
1
/
(851)
30 
1
/
4 
(768)
61
 
(1549)
42
 
(1064)
54 
7
/
8 
(1393)
FAN
L
C5X-LEP
17 
1
/
4 
(438)
3 In. 
(77 mm) 
Required 
Air Gap
1
/
(183)
19 
5
/
8 
(499)
5
/
8 
(92)
26 
1
/
(665)
Refrigeration 
Outlet
7
/
8 
(123)
Electrical 
Case to Case 
Connections
17 
1
/
(436)
81 
3
/
4 
(2077)
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels, Low Front
Impact  
Excel
C5X-LEP
Dairy/Delicatessen/Produce
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for