Hitachi BZ-1 사용자 가이드

다운로드
페이지 283
64
OPTION menu
Item
Description
SERVICE
(continued)
COMMUNICATION
(continued)
COMMUNICATION TYPE
Select the communication type for transmission via 
the CONTROL port.
NETWORK BRIDGE 
 OFF
NETWORK BRIDGE: Select this type, if it is required 
to control an external device as a network terminal, 
via this projector from the computer. 
The CONTROL port doesn't accept RS-232C  
commands (
Network Bridge Function in the 
User’s Manual - Network Guide)
OFF: Select this mode to receive RS-232C 
commands using the CONTROL port. 
• OFF is selected as the default setting. 
• When you select the NETWORK BRIDGE, check 
the item, TRANSMISSTION METHOD (
below).
SERIAL SETTINGS
Select the serial communication condition for the 
CONTROL port.
BAUD RATE
4800bps 
 9600bps  19200bps  38400bps
      
 PARITY
NONE 
 ODD  EVEN
    
• The BAUD RATE is fixed to 19200bps and PARITY 
is fixed NONE when the COMMUNICATION TYPE 
is set to OFF (
above).
TRANSMISSION METHOD
Select the transmission method for communication by 
the NETWORK BRIDGE from the CONTROL port.
HALF-DUPLEX 
 FULL-DUPLEX
HALF-DUPLEX: This method lets the projector 
make two way communication, but only one 
direction, either transmitting or receiving data, is 
allowed at a time.
FULL-DUPLEX: This method lets the projector 
make two way communication, transmitting and 
receiving data at the same time.
• HALF-DUPLEX is selected as the default setting.
• If you select HALF-DUPLEX, check the setting of 
the item RESPONSE LIMIT TIME (
65).
(continued on next page)