Delfield ACR-26S 설치 설명서

다운로드
페이지 20
Customer service FAX (517) 773-3210
5
MCII Tempatrol® Controls
RESET
®
CHECK SYSTEM DEFROST
AM PM
CLEAN
CONDENSER
DOOR AJAR
RESET
•  Turns off alarms
•  Terminates the cur-
rent defrost cycle
•  Returns display of 
cabinet temperature
TIME
•  Displays the current 
time (if set)
•  Allows setting the 
clock by pressing 
UP 
and 
DOWN buttons
•  Starts a manual 
defrost cycle when 
pressed simul-
taneously with 
DEFROST
DEFROST
•  Displays current 
defrost setting 
(A,3,4,6 or 8)
•  Allows setting 
defrost setting and 
times by pressing 
UP and DOWN but-
tons
•  Starts a manual 
defrost cycle when 
pressed simulta-
neously with 
TIME
TEMP
•  Displays current tem-
perature set point
•  Allows modification 
of set point by press-
ing 
UP and DOWN 
buttons
UP
•  When time is 
displayed, changes 
time forward
•  When defrost set-
ting is displayed, 
moves forward 
through choices
•  When first defrost 
time is displayed, 
moves the hour    
forward
•  When set point is 
displayed, moves set 
point up one degree
DOWN
•  When time is 
displayed, changes 
time backward
•  When defrost set-
ting is displayed, 
moves backward 
through choices
•  When first defrost 
time is displayed, 
moves the hour 
backward
•  When set point is 
displayed, moves 
set point down one 
degree
MCII Tempatrol® Display Functions
Normal display
The normal display is the interior cabinet temperature in 
degrees Fahrenheit. (For details on changing the display 
to show the temperature in degrees Celsius, see page 10.) 
Pressing the 
RESET button always displays current temper-
ature. By pressing 
TEMP, you can read the set point of the 
interior cabinet. The display will automatically return to the 
current interior temperature after one minute.
It is not unusual for the interior temperature to rise rapidly 
when a door is opened. The temperature displayed is usu-
ally the warmest temperature inside the unit. This is done 
purposely to make sure that the entire storage area is always 
represented by the display and assures that the refrigeration 
system is activated quickly to return the storage area to its 
correct temperature.
Remember that the temperature displayed represents a pre-
cision measurement of the actual air temperature, not an 
average temperature. When a door is opened, the cold air 
literally “falls out” and warm air rushes in. What the display 
shows is real, and provides more accurate control.
Normal display
The normal display is the interior cabinet temperature in 
degrees Fahrenheit. (For details on changing the display 
to show the temperature in degrees Celsius, see page 10.) 
Pressing the RESET button always displays current temper-
ature. By pressing TEMP, you can read the set point of the 
interior cabinet. The display will automatically return to the 
current interior temperature after one minute.
It is not unusual for the interior temperature to rise rapidly 
when a door is opened. The temperature displayed is usu-
ally the warmest temperature inside the unit. This is done 
purposely to make sure that the entire storage area is always 
represented by the display and assures that the refrigeration 
system is activated quickly to return the storage area to its 
correct temperature.
Remember that the temperature displayed represents a pre-
cision measurement of the actual air temperature, not an 
average temperature. When a door is opened, the cold air 
literally “falls out” and warm air rushes in. What the display 
shows is real, and provides more accurate control.
Normal display
The normal display is the interior cabinet temperature in 
degrees Fahrenheit. (For details on changing the display to 
show the temperature in degrees Celsius, see page 
10.) Pressing the 
RESET button always displays cur-
rent temperature. By pressing 
TEMP, you can read 
the set point of the interior cabinet. The display will 
automatically return to the current interior tempera-
ture after one minute.
It is not unusual for the interior temperature to rise 
rapidly when a door is opened. The temperature 
displayed is usually the warmest temperature inside 
the unit. This is done purposely to make sure that 
the entire storage area is always represented by the 
display and assures that the refrigeration system is 
activated quickly to return the storage area to its cor-
rect temperature.
Remember that the temperature displayed represents 
a precision measurement of the actual air tempera-
ture, not an average temperature. When a door is 
opened, the cold air literally “falls out” and warm air 
Flashing temperature disply
A flashing temperature display can be caused by four situa-
tions, and is the first signal of a possible problem:
1.  The unit has been started, or restarted after a 
power loss, and has not yet reached set tempera-
ture.
2.  The interior cabinet is over temperature. This 
occurs when a freezer reaches 32°F (0°C) or 
when a refrigerator reaches 65°F (18°C). This 
condition will stop when the temperature returns 
to a reading below these warning levels.
3.  Long duty cycle. The unit has been running 
for one continuous hour without a door being 
opened. This condition will stop if RESET is 
pressed, a door is opened, or if the compressor 
shuts off.
4.  The door has been ajar for over one minute. This 
condition will stop if the door is closed.
Continued on the next page
S
T P
E S
S
T P
E S