Service – Calibration and Troubleshooting
Hot & Cold (Ambient) Water Calibration
H2O Calibration Instructions
H2O Calibration applies to the following :
A. Hot Water flow rate
B. Cold Water (ambient) flow rate
B. Cold Water (ambient) flow rate
Calibration routine-Note: H2O Calibration is a factory
setting & should not need re-calibration unless
A dispensing valve is replaced or the measured
dispense volume does not match the displayed setting
A dispensing valve is replaced or the measured
dispense volume does not match the displayed setting
Step 1
Press & hold Button 2 “Settings”
After approximately 5 seconds
Display will change to”- - -”
After approximately 5 seconds
Display will change to”- - -”
- - -
H2o
Step 2
Continue holding for approximately
8 more seconds until display
Changes to “con”. Do not release
button, after approx 8 more seconds
Display will change to “H2o”
NOTE: MACHINE MUST BE AT OPERATING TEMPERATURE PRIOR
TO CALIBRATING HOT WATER FLOW RATE.
TO CALIBRATING HOT WATER FLOW RATE.