Temperature Override - Turns the tank heater on at the start of a brew cycle to the maximum setting for 1 minute. 
This assures a more uniform brew temperature and reduces the recovery time required for rebrewing. As an 
additional safety check on the heater circuit the control board continuously monitors how long the element is on. If 
the run time exceeds 30 minutes the tank element is shut down and an error message is produced. See the 
following section for an explanation of all error messages. 
 
Service Alert System - Monitors key elements of brewer operation and shuts brewer down if an error condition 
occurs. If the tank heater element runs for more than 30 minutes continuously, the fill valve runs for more than 6 
minutes (1-1/2 minutes during brew cycle) continuously without probe contact or if the temperature sensor opens or 
shorts this will trigger the system to shut down. The service alert system illuminates the various indicator lights on 
the front of the brewer to indicate the type of error encountered. The table below list the different error codes 
produced by the service alert system, the posssible cause and what to check when the brewer will not operate. 
 
Error Code: 
Problem Area: 
Cause: 
Check: 
Autobrew/Heating & 
brewing lights on steady 
Water Fill 
System detects that fill valve has run for 6 min. (1-1/2 
min. during brew cycle) w/o making contact with probe. 
Water supply to brewer, water filters & 
water probe to see if limed up. 
Autobrew/Heating & 
ready lights on steady 
Tank Heater 
Tank heating system has run for 20 minutes. 
Tank heater relay, tank heater,  
limit thermostat. 
Auto Brew/heating& 
ready lights on steady 
See cause 
Blue wire is not connected to either black or  
Red wire 
 Blue wire connection. Black to enable 
Auto Arm or red to Disable Auto Arm 
Autobrew/Heating & half 
brew lights on steady 
Temperature Probe 
Thermistor is open. 
Replace Thermistor. 
Autobrew/Heating & full 
brew lights on steady 
Temperature Probe 
Thermistor shorted. 
Replace Thermistor. 
IN CASES WHERE THERE IS A HEATER OR FILL PROBE ERROR, THE BREWER CAN BE RESET BY HOLDING DOWN THE 
CANCEL BUTTON FOR APPROXIMATELY 5 SECONDS.  ERROR WILL CLEAR. 
REPLACEMENT PARTS LIST 
Part No  Description 
Part No  Description 
Tank Components 
Expansion Pan Parts 
110777  Element, tank, 1250 W 120 V 
111164  O-ring, exp pan, 6.484 ID x .139 W 
110792  Element, tank, 1400 W 120 V 
111176  Spring, check valve, expansion pan 
110791  Element, tank, 1550 W 120 V 
111226  Cover, expansion pan 
110762  Protector, element 
111227  Pan, expansion 
110764  Washer, element 
111228  Retainer, Ball 
110765  Screws, element 
111401  Ball, 1/2 diameter 
110766  Washer, element, locking 
111402  Screw, #6 x 3/8", for plastic 
110767  Ring tab 
111403  Screw, #4 x 3/8", for plastic 
110752  Seal, element 
111519  Level probe 
110758  O-ring, Tank, 5.975 ID x .275 W 
704222  Gasket, pan outlet, 4 holes 
111080  Lid, plastic 
110978  Sprayhead fitting ass'y 
111153 Sensor, 
temperature 
 
 
  
Electrical 
Components 
Valves and faucet 
110626  Switch, On/Off, DPST, rocker 
111050  Valve, Inlet 
110378  Board, display 
110305  Flow control, PDS, low flow 
111515  Board, control 
111396  Faucet 
105057  Relay, heater, 12 V coil 
110506  Clamp, drain tube 
 
 
111517  Insert, 3/8 tube insert 
Miscelaneous components 
  
110985 
Brewbasket 
Tubing and gaskets 104010 
Brewrail, 
RH 
152218  Tubing, Silicone, 1/4 ID x 3/8 OD 
104011  Brewrail, LH 
152213  Tubing, Silicone, 3/8 ID x 5/8 OD 
100024  Sprayhead, S/S, 5 hole 
102544  Tubing, Silicone, 3/8 ID x 1/2 OD 
201173  Nut, sprayhead, 7/16-20 
101931  Tubing, Silicone, 5/8 ID x 3/4 OD 
701985  Sprayhead tube assembly 
111105  Nipple, fitting, Silicone 
110381  Spacer, 5/16" hex, display board 
100025  Gasket, sprayhead 
110991  Screw, 6-32 x 3/16, PPHMS, Nylon 
102836  Grommet, probe & thermistor 
108014  Access Plate 
 
 
111198  Standoff, .144 ID x 3/8 L, Brass