Avoid Service Checklist
Before  calling  for service,  review  this  list. It  may  save  you time and expense. This list 
includes common occurrences that are  not  the result of defective workmanship or 
  OCCURRENCE                        SOLUTION
   Air conditioner will not operate.  Wall plug disconnected. Push plug firmly into wall outlet.
House  fuse  blown  or circuit  breaker  tripped.  Replace fuse with time delay type or reset 
circuit breaker.
Control is OFF. Turn control On and set to desired FAN or COOL setting.
   Air from unit does not feel cold
   enough.
Room temperature below 60 F (15 C). Cooling may not occur until room  temperature
rises above 60 F (15 C).
Temperature  sensor  touching cold coil, located  behind  air  filter.  Straighten  away 
from coil 
Air conditioner cooling, but
room is too warm- ice forming
on cooling coil behind 
decorative front.
Outdoor  temperature  below  60 F (15 C).  To  defrost  the coil,  set  selector  to  FAN
position. 
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set
selector to FAN ONLY mode..
Temperature  is  too  low  for  night-time cooling. To defrost  the coil, set to FAN ONLY 
mode. Then, set temperature to a higher number.
Air conditioner cooling, but 
room is too warm-NO ice
forming on cooling coil
behind decorative front.
Dirty air filter-air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is  too high. Set temperature to a lower number.
Current device tripped. Preset RESET  button.
Reset to a lower temperature.
Compressor  shut-off  by  changing  modes.  Wait  approximately 3 minutes, and listen for
compressor to restart when set in the COOL mode.
Vent set at OPEN position. Set vent at CLOSED position for maximum cooling.
Air direction louvers positioned improperly. Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture, etc.-restricts air distribution.Clear 
blockage in front of unit. 
Doors,   windows,  registers,  etc,  open- cold  air  escapes.  Close  doors,  windows,
registers, etc.
Unit  recently  turned  on  in  hot  room,  allow additional time to remove “ stored heat”
from walls, ceiling, floor and furniture.
Air conditioner turns on and 
off rapidly.
Dirty air filter-air restricted. Clean air filter. 
Outside  temperature  extremely  hot.  Set  FAN  speed  to a faster setting to bring air
past cooling coils more frequently.
Noise when unit is cooling
Air movement sound. This is normal. If too loud, set to a slower FAN setting.
Sound  of  fan  hitting  water-moisture  removal system. This is normal when humidity 
is high. Close doors windows and registers.
Window  vibration- poor  installation.  Refer  to  installation instructions or check with 
installer.
Water dripping INSIDE when
unit is cooling.
Improper   installation.  Tilt  air   conditioner  slightly  to  the  outside  to  allow   water 
drainage. Refer to installation instructions -check with installer.
Water dripping OUTSIDE when
unit is cooling.
Unit  removing  large  quantity  of  moisture  from  humid room.  This  is normal during
excessively humid days. 
Room too cold
Setting too low. Increase temperature setting.