Writing data to Flash
Done
4
When you are finished using the facility, log out of the application switch.
You can now access the Gigabit Ethernet port directly via Telnet. 
Configuring the 10/100 Ethernet Management Port
The 10/100BT Ethernet management port provides dedicated remote access to the 
application switch using TCP/IP. It supports Telnet using the command-line interface. 
The 10/100BT port is designed to be used as an out-of-band management port only. It does 
not function as a load balancing port.
To use the management interface, you must assign it an IP address and subnetwork 
mask, using the following command:
config mgmt ip <ipaddress> / <netmask bit length>
The 10/100BT port has a separate routing table. By default, no routes are installed in the 
routing table. You must explicitly configure routes. After the IP address has been 
configured, install a route for the network, using the following command:
config mgmt iproute dest-ip <ipaddress> gateway <ipaddress>
You can add additional routes, as needed.
The configuration of management port information is executed immediately. You 
do not need to use the 
build 
command.
The following example configures an IP address and installs two network routes:
station1:4 # config mgmt ipaddress 10.10.10.2 / 24
station1:5 # config mgmt iproute dest-ip 10.10.10.0 gateway 10.10.10.1
station1:6 # config mgmt iproute dest-ip 10.10.11.0 gateway 10.10.10.1