Chapter 6—Configuration Command Reference 
202 
Trakker Antares 2400 Family System Manual 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Serial 
Port 
 
Bar Codes:  To disable LRC, scan one of these bar codes: 
Disable LRC for COM1 
Disable LRC for COM2 
*$+YF1.0* 
*$+YF2.0* 
*$+YF1.0* *$+YF2.0* 
Disable LRC for COM3 
Disable LRC for COM4 
*$+YF3.0* 
*$+YF4.0* 
*$+YF3
.
0* *$+YF4
.
0* 
 
Or:  To enable LRC, scan one of these bar codes: 
Enable LRC for COM1 
Enable LRC for COM2 
*$+YF1.1* 
*$+YF2.1* 
*$+YF1.1* *$+YF2.1* 
Enable LRC for COM3 
Enable LRC for COM4 
*$+YF3.1* 
*$+YF4.1* 
*$+YF3
.
1* *$+YF4
.
1* 
Maximum Retries 
 
Terminals:  2415, 2425, 2435, 2455, 2475, and 2485/6. 
 
Description:  Defines the number of times the terminal will attempt to send a 
disconnect request message to the Intermec Gateway or DCS 30X. The 
terminal sends connect and disconnect request messages to the Intermec 
Gateway or DCS 30X when you turn the terminal on and off. 
Tip: Intermec strongly recommends that you use the optimum setting of 7 
retries. 
 
Syntax: NRdata 
Acceptable values for data are: 
Terminal retries indefinitely 
1-99  Number of retries 
 
Default: 7 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Advanced 
Network 
 
Bar Codes:  To set the default number of maximum retries, scan this bar code: 
Default Maximum Retries 
*$+NR7* 
*$+NR7*