2 to 1 Configuration (RVP_Direct)
The EXTender Remote Unit communicates with the Gateway installed at the corporate facility. The
Gateway can connect to two different EXTender remote units using RVP_Direct to both WAN Ports. The
first remote is connected to WAN1 of the Gateway and the second remote is connected to WAN2 of the
Gateway. Once you configure the Gateway to accommodate two separate remote units, you must
configure the following EXTender parameters:
Remote Number: This number (1 or 2) identifies the Gateway WAN port connected to the EXTender.
Gateway Port Offset: This parameter is used to allow the lower port numbers on Remote 2 access to the
Gateway unit.
Example: If the Gateway port offset is set to 4, when port 1 on the Remote connects, it connects to port 5
on the Gateway.
Procedure
1. Access the Connect menu using the following path:
Gateway can connect to two different EXTender remote units using RVP_Direct to both WAN Ports. The
first remote is connected to WAN1 of the Gateway and the second remote is connected to WAN2 of the
Gateway. Once you configure the Gateway to accommodate two separate remote units, you must
configure the following EXTender parameters:
Remote Number: This number (1 or 2) identifies the Gateway WAN port connected to the EXTender.
Gateway Port Offset: This parameter is used to allow the lower port numbers on Remote 2 access to the
Gateway unit.
Example: If the Gateway port offset is set to 4, when port 1 on the Remote connects, it connects to port 5
on the Gateway.
Procedure
1. Access the Connect menu using the following path:
Path:
Remote->Configuration->Connect
The following menu appears:
Figure 22: Gateway Port Offset
2. Press
the
Æ
key, then the Èkey to access the Gateway Port Offset parameter. Enter a digit (0-12) to
set the value and press Enter.
3. Press
the
Çand Æ
keys to access the RVP_Direct menu. The RVP_Direct menu on page 20
appears.