Lexicon MC-12 사용자 가이드

다운로드
페이지 106
Lexicon 
MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
7.3.6  Get Zone 2 Status (MC-12, MC-1) 
This command is a request to MC-12 for current Zone 2 Status. MC-12 will respond with “Zone2 Status 
Packet”. 
 
This command has been maintained for backward compatibility with MC-1.  In order to maintain backward 
compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data 
Description.  MC-12 users should be using the command described in 
 
7.3.6.1  Command Packet Description 
Application Header: 
  
Command DC_CMD_GET_ZONE2_STATUS 0x17 
Data Count  0 
0x00 
Application Data: 
  
  
N/A 
  
 
7.3.6.2  Zone2 Status Response Packet 
Application Header: 
  
Command DC_RESP_ZONE2_STATUS 
0x82 
Data Count 5 
0x05 
Application Data: 
  
Data[0] Zone2 
Volume 
nn 
Data[1] 
Assigned Zone 2 Input 
nn 
Data[2] 
Zone2 Mute Active 
nn 
Data[3] Record 
Active 
nn 
Data[4] Zone2 
Balance 
nn 
 
7.3.6.3 Data Description 
 
 
Zone2 Volume: 
Data Type: 
 
Unsigned 8 bit integer. 
Maximum Value: 92 
Conversion: 
 
0  =  -80 dB 
   92 
+12 
dB 
 
 
Assigned Zone 2 Input: 
 
 
Indicates the Zone 2 input that is currently assigned for the zone 2 outputs. 
Data Type: 
 
Unsigned 8 bit integer. 
Definition/Conversion: 
 
 
Zone2 Mute Active: 
Data Type: 
 
Boolean. 
TRUE:   
 
Zone2 Outputs are active. 
FALSE:  
 
 
Zone 2 Outputs are not active. 
 
 
Record Active: 
Data Type: 
 
Boolean. 
TRUE:   
 
Record Zone Output is active 
FALSE:  
 
 
Record Zone Output is not Active. 
© 2005 Harman Specialty Group All rights reserved. 
 
23 of 106