Lexicon MC-12 사용자 가이드

다운로드
페이지 106
Lexicon 
MC-12 Serial Communications Protocol 
 
Printed on: 07/13/05 
Application Header: 
  
Command DC_CMD_SET_REC_INPUT 
0x25 
Data Count  1 
0x01 
Application Data: 
  
Data[0] InputId 
nn 
 
7.3.22.2 Data Description 
InputId: 
 
Data Type: 
 
Unsigned 8 bit Integer 
Description/Conversion: 
7.3.22.3 MC-12 Response: 
If the Input Id is a valid MC-12 input then the MC-12 will make the request Input the active record input. 
7.3.22.4 Data Validation: 
The InputId must be a valid Input Id.  If it is not the MC-12 will respond with a NAK packet and error 
code DC_INVALID_INPUT. If the input is assigned the MC-12 will respond with an ACK Packet. 
7.3.23  Clear Record Input (MC-12, MC-1) 
Clears or unassigns the Record input.  If Record is active, this command will set the Record Input to OFF 
7.3.23.1 Packet Description 
Application Header: 
  
Command DC_CMD_CLEAR_REC_INPUT  0x26 
Data Count  1 
0x01 
Application Data: 
  
Data[0] InputId 
nn 
 
7.3.23.2 Data Description 
InputId: 
 
This value is not used by MC-12. 
 
Data Type: 
Unsigned 8 bit Integer 
7.3.23.3 MC-12 Response 
The MC-12 will set the active record input to OFF. 
7.3.23.4 Data Validation 
The InputId is not used. 
 
7.3.24  Set Zone2 Volume (MC-12, MC-1) 
Commands MC-12 to set the Zone 2 volume with the value in this packet. 
 
This command has been maintained for backward compatibility with MC-1.  In order to maintain backward 
compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data 
Description.  MC-12 users should be using the command described in 
 
© 2005 Harman Specialty Group All rights reserved. 
 
29 of 106