Electrical Shock Hazard
• Plug unit only into grounded electrical outlet.
• Do not use an extension cord or plug adapter with this unit.
• Do not operate unit with decorative front or filter removed. 
• Failure to follow these precautions could result in electrical
shock, fire or personal injury.
• If the air conditioner has a serial plate rating of 115 volts and
greater than 7.5 amps it must have its own fuse or circuit
breaker, and no other device or unit should be operated on
that fuse or circuit breaker. If the air conditioner has a serial
plate rating of 230 volts it must have its own fuse or circuit
breaker, and no other device or unit should be operated on
that fuse or circuit breaker.
• We recommend that a qualified electrician install unit in
accordance with the National Electrical Code and local codes
and ordinances.
• Do not operate this air conditioner without proper time delay
circuit protection. Refer to serial plate for proper power supply
requirements.
• Use copper conductors of correct wire gauge and 
protector size only.
• Do not alter cord or plug end. Do not remove warning label 
on cord.
Important Grounding Requirements
• Air conditioner has a three-prong grounding plug on the power
supply cord, which must be plugged into a properly grounded
three-prong wall receptacle for your protection against possible
shock hazard. For models up to and including 7.5 amperes use a
grounding type wall receptacle to match the cord plug. 
• For models above 7.5 amperes use a single outlet grounding type
wall receptacle to match the cord plug. 
Additional Safety Precautions
• Do not cut, alter or remove any of the expanded
polystyrene (white foam) inside this air conditioner.
• Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance. The
fumes can create a fire hazard or explosion.
• Do not introduce objects in the air discharge area. This
could cause permanent damage to your unit.
• Do not pour liquids on the air conditioner as this could
cause a malfunction. With the unit unplugged, use a damp
cloth for cleaning  your unit.
• Avoid using strong solvents to clean the air conditioner. 
• Clean the air conditioner filter every two weeks to avoid
overheating caused by air obstruction. Do not operate
without filter.
• Do not obstruct the air intake area of your air conditioner,
as this could cause overheating, thus activating the units
security switch and shutting off the unit.
• Do not block air circulation to outside louvers of cabinet.
• Do not block air flow inside with blinds, curtains, or
furniture, or outside with shrubs, enclosures, or other
buildings.
• Do not run the air conditioner with an outside protective
cover in place. This could result in fire or mechanical
damage within the air conditioner.
Three-prong grounding plug. 
Do not alter plug end.
Single outlet grounding wall
receptacle
Grounded three-prong wall
receptacle
A
A
B
B
C
C
Warning
Warning
RECOMMENDED CIRCUIT WIRE SIZES  
(As installed per building code) :
PROTECTOR SIZE
WIRE GAUGE
15 AMP #14 MINIMUM
20 AMP #12 MINIMUM
30 AMP #10 MINIMUM
125V
15A
250V  
20A
250V
30A
250V  
15A
ELECTRICAL REQUIREMENTS 
& SAFETY PRECAUTIONS
INSTALLATION