Aten kh-0116 사용자 설명서

다운로드
페이지 70
 Chapter 2. Installation and Operation
15
CE-250R Operation
With the Remote Console installed, the default situation is for both the Local 
and Remote consoles to be active. The KH0116 and the CE-250R have two 
LEDs each to indicate the Local/Remote operating status, as shown in the 
tables, below:
KH0116 (Local Console):
CE-250R (Remote Console):
LED
Operating Mode
Local
Auto
Local
Lights to indicate that 
the Local Console is 
active (the Remote 
LED is out).
1. Lights when the local console is active (the 
Remote LED is out)
2. Turns off when the remote console is 
active (the Remote LED turns on)
3. Flashes on and off alternately with the 
Remote LED when neither console is 
active.
Remote
The LED is Off.
1. Lights when the remote console is active 
(the Local LED is out)
2. Turns off when the local console is active 
(the Local LED turns on)
3. Flashes on and off alternately with the 
Local LED when neither console is active.
LED
Indication
Power
1. Lights steadily to indicate that the connection to the Local Unit 
is ok.
2. Flashes when there is a problem with the connection to the 
Local Unit.
On Line
1. Lights when the remote console is active.
2. Is Off when the local console is active.
3. Is Off when there is a problem with the connection to the Local 
Unit.
kh0116-v2.book  Page 15  Wednesday, March 22, 2006  4:53 PM