Marvel 60cim-ss-f 사용자 가이드
USING YOUR REFRIGERATOR
Setting the temperature control:
Initially set the cold control midway between the numbers
(between the #3 and #4).After at least 2 hours adjust to
the temperature that suits you. The higher the number you
select, the cooler the temperature. (See figure 5). After
loading the refrigerator allow at least 24 hours for your
refrigerator to reach a new temperature setting.
Initially set the cold control midway between the numbers
(between the #3 and #4).After at least 2 hours adjust to
the temperature that suits you. The higher the number you
select, the cooler the temperature. (See figure 5). After
loading the refrigerator allow at least 24 hours for your
refrigerator to reach a new temperature setting.
The refrigerator section temperature of the unit can be ad-
justed using the adjusting slide located in the left side and
rear of the refrigeration section. Turn in the cold direction
indicated to make the refrigeration section colder and the
opposite direction to warm the refrigeration section.
justed using the adjusting slide located in the left side and
rear of the refrigeration section. Turn in the cold direction
indicated to make the refrigeration section colder and the
opposite direction to warm the refrigeration section.
Cold control
underneath door
in grille
underneath door
in grille
Figure 5
Defrosting
This unit uses an electronic control system to control both
defrost and refrigeration functions. This feature eliminates
the inconvenience of manual defrosting of the evaporator
in normal conditions. If commodities or ice accidently clogs
the drip tray, the obstruction must be removed for proper
defrost performance. It is normal for some water droplets
to be left on the evaporator or drip tray. These will refreeze
and be removed in the next defrost cycle.
This unit uses an electronic control system to control both
defrost and refrigeration functions. This feature eliminates
the inconvenience of manual defrosting of the evaporator
in normal conditions. If commodities or ice accidently clogs
the drip tray, the obstruction must be removed for proper
defrost performance. It is normal for some water droplets
to be left on the evaporator or drip tray. These will refreeze
and be removed in the next defrost cycle.
Defrosting is factory set to run after the compressor has
run approximately 12 hours. For climates with high humid-
ity levels and / or repeated door openings, an optional 6
hour compressor run time is already programmed into the
control. A switch will have to be set at the control for this
change to take place (consult your distributor or authorized
service center).
run approximately 12 hours. For climates with high humid-
ity levels and / or repeated door openings, an optional 6
hour compressor run time is already programmed into the
control. A switch will have to be set at the control for this
change to take place (consult your distributor or authorized
service center).
A drip tray heater is located in the unit for proper removal of
condensation. The heater will remain on as long as the unit
is plugged in. The control knob will not turn the heater off.
Unplug or disconnect power to the unit if you are planning to
leave the unit off or unattended for extended periods of time.
condensation. The heater will remain on as long as the unit
is plugged in. The control knob will not turn the heater off.
Unplug or disconnect power to the unit if you are planning to
leave the unit off or unattended for extended periods of time.
Icemaker operation
Make certain water pressure is at least 20 psi and no
•
more than 120 psi and the water is turned on.
The unit must be installed level for proper icemaker
The unit must be installed level for proper icemaker
•
operation.
The shutoff arm wire must be down in its lowest position
The shutoff arm wire must be down in its lowest position
•
for the icemaker to operate.
Make sure there are no obstructions in the fan inlet and
Make sure there are no obstructions in the fan inlet and
•
outlet. The fan is located beside the icemaker at the top
of the freezer section.
When the freezer section and icemaker unit has suf-
of the freezer section.
When the freezer section and icemaker unit has suf-
•
ficiently cooled, the icemaker will harvest ice cubes
automatically.
When the ice bucket is full, the ice maker will automati-
automatically.
When the ice bucket is full, the ice maker will automati-
•
cally shut off.
You may manually stop the icemaker by raising the shut
You may manually stop the icemaker by raising the shut
•
off arm to the locking position at the up most position.
Arm down, icemaker
will operate
will operate
Arm up, stops operation
When operation of the appliance is to be discontinued
for any length of time, the ice cube cavity in the icemaker
should be emptied and dried. The water supply and power
supply should also be shut off and the ice bucket should be
emptied and cleaned.
for any length of time, the ice cube cavity in the icemaker
should be emptied and dried. The water supply and power
supply should also be shut off and the ice bucket should be
emptied and cleaned.
If the ice is not used regularly, it will clump together with
time. For best ice results, discard ice in the bin as required
and allow the icemaker to make a new fresh batch of ice.
time. For best ice results, discard ice in the bin as required
and allow the icemaker to make a new fresh batch of ice.
5
Figure 6
Cover
pulls off
pulls off
Water adjustment screw behind cover
on side of housing
on side of housing