Panasonic aj-spc700 사용자 설명서

다운로드
페이지 124
113
8
Chapter 8 Menu Description Tables 
(continued)
8-5-7 USER SW GAIN
8-5-8 IRIS
8-6 MAIN OPERATION
8-6-1 BATTERY/P2CARD
The ____ in the Adjustable Range column indicates the
preset mode. 
Items/
Data Saved 
Adjustable 
Range 
Remarks 
S.GAIN
30 dB
_
Select whether or not to enable 30dB 
for SUPER GAIN. 
_: Enable. 
 • : Disable. 
– C U F E
36 dB
_
Select whether or not to enable 36dB 
for SUPER GAIN. 
_: Enable. 
 • : Disable.
– C U F E
Items/
Data Saved 
Adjustable 
Range 
Remarks 
A.IRIS LEVEL
000
 : 
050
 : 
100
Set the target value for auto iris. 
– C U F E
A.IRIS PEAK/
AVE
000
 : 
040
 : 
100
Determine the peak-to-standard ratio 
for the auto iris. 
A larger value sets the auto iris to 
respond to the peak in the IRIS 
detection window, while a smaller value 
sets it to respond to the average value 
in the window. 
– C U F E
A.IRIS MODE
NORM1
NORM2
CENTR
Select the auto iris detection window. 
NORM1:The window closer to the center 
of the screen. 
NORM2:The window closer to bottom of 
the screen. 
CENTR: The spot window in the center of 
the screen. 
– C U F E
S.IRIS LEVEL
000
 : 
080
 : 
100
Set the target value for the super iris. 
– C U F E
IRIS GAIN
CAM
LENS
Select which unit controls IRIS GAIN. 
<Note>
Lenses with an extender, such as
C2, 
C0.8 sold before FUJINON DIGI 
POWER, perform IRIS compensation 
while enabling the extender. Therefore, 
if this setting is switched to CAM, the 
camera’s iris control will not operate 
properly. 
– C U F E
IRIS GAIN 
VALUE
01
 : 
08
 : 
20
Set the adjustable value for IRIS GAIN. 
This setting is effective when CAM is 
selected for IRIS GAIN. 
– C U F E
Items/
Data Saved 
Adjustable 
Range 
Remarks 
BATTERY 
SELECT
PRO14
TRIM14
HYTRON50
HYTRON100
HYTRON120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Select the battery to use. Remaining 
capacity detection is also performed 
according to the selected battery. 
The selectable battery types change 
depending on the settings under [8-6-2 
BATTERY SETTING1]
 and [8-6-3 
BATTERY SETTING2]
– C U F –
EXT DC IN 
SELECT
AC_ADPT
PRO14
TRIM14
HYTRON50
HYTRON100
HYTRON120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Set the remaining capacity detection 
type when a battery is connected to the 
DC IN connector. Remaining capacity 
detection is also performed according 
to the selected battery type. 
The selectable battery types change 
depending on the settings under [8-6-2 
BATTERY SETTING1]
 and [8-6-3 
BATTERY SETTING2]

<Note>
The % display is disabled even when a 
digital battery is connected to the DC IN 
connector. 
– C U F –
BATT NEAR 
END ALARM
ON
OFF
Select whether or not to set the alarm 
to beep for BATT NEAR END ALARM. 
– C U F –
BATT NEAR 
END CANCEL
ON
OFF
If set to ON, the warning tone and 
indication can be canceled by pressing 
the MODE CHECK button when BATT 
NEAR END ALARM is triggered. 
– C U F –
BATT END 
ALARM
ON
OFF
Select whether or not to set the alarm 
to beep for BATT END ALARM. 
– C U F –
BATT REMAIN 
FULL
70%
100%
Set the display content of the remaining 
battery capacity indicator bars in the 
display window when using a digital 
battery. 
70%:  Indicate FULL at 70% capacity. 
100%:  Indicate FULL at 100% capacity. 
– C U F –