3com 8807 사용자 가이드
NQA Configuration
863
Set the name of the VPN
instance
instance
vpn-instance name
Optional;
By default, no name of the
VPN instance is set
VPN instance is set
Set the source IP address of
this test
this test
source-ip ip-address
Optional;
By default, no source IP
address is configured. The
system uses the IP address of
the source interface as the
source IP address.
address is configured. The
system uses the IP address of
the source interface as the
source IP address.
Set the source interface
source-interface {
interface-name |
interface-type
interface-number }
interface-name |
interface-type
interface-number }
Optional;
By default, no source interface
is configured
is configured
Assume the connection mode
between the destination
address and the equipment
enabling the test as direct
connection mode
between the destination
address and the equipment
enabling the test as direct
connection mode
sendpacket passroute
Optional;
By default, no such
assumption
assumption
Set the number of the test
results that can be stored in
the history record
results that can be stored in
the history record
history-records number
Optional;
By default, 50 test results can
be stored in the history
record.
be stored in the history
record.
Set the condition (probe) of
sending Trap information to
the network management
system
sending Trap information to
the network management
system
send-trap { all | {
probefailure | testcomplete
| testfailure } * }
probefailure | testcomplete
| testfailure } * }
Optional;
By default, no Trap
information is sent to the
network management system.
information is sent to the
network management system.
Set the times of constant
probe fails after which the
Trap information is sent to the
network management system
probe fails after which the
Trap information is sent to the
network management system
probe-failtimes times
Optional;
By default, the system sends
the Trap information to the
network management system
after one probe fail.
the Trap information to the
network management system
after one probe fail.
Set the Trap information filter
condition (test)
condition (test)
test-failtimes times
Optional;By default, NQA
sends the Tap information to
the network management
system after one NQA test
fails.
sends the Tap information to
the network management
system after one NQA test
fails.
Set the automatic test interval frequency interval
Optional;
The default interval time is 0,
that is, no automatic test is
performed;
that is, no automatic test is
performed;
Configure the interval>0,
then the system performs one
automatic test every
configured interval time
then the system performs one
automatic test every
configured interval time
Enable the test
test-enable
Required; (ignore this
configuration if you choose
the frequency interval
command to enable the
automatic test); generally, use
this command to enable tests.
configuration if you choose
the frequency interval
command to enable the
automatic test); generally, use
this command to enable tests.
Display the test result
display nqa { results |
history } [
administrator-name test-tag ]
history } [
administrator-name test-tag ]
The display command can be
executed in any view.
executed in any view.
Table 818 Introduction to the configuration tasks of the ICMP test in NQA
Operation Command Remarks