3com S7906E 설치 설명서

다운로드
페이지 2621
 
1-32 
[SwitchA-vlan100] mld-snooping enable 
[SwitchA-vlan100] mld-snooping drop-unknown 
# Configure MLD snooping querier feature in VLAN 100. 
[SwitchA-vlan100] mld-snooping querier 
[SwitchA-vlan100] quit 
2)  Configure Switch B  
# Enable IPv6 forwarding and enable MLD snooping globally.  
<SwitchB> system-view 
[SwitchB] ipv6 
[SwitchB] mld-snooping 
[SwitchB-mld-snooping] quit 
# Create VLAN 100, add GigabitEthernet 2/0/1 through GigabitEthernet 2/0/4 into VLAN 100. 
[SwitchB] vlan 100 
[SwitchB-vlan100] port gigabitethernet 2/0/1 to gigabitethernet 2/0/4 
# Enable the MLD snooping feature and the function of dropping unknown IPv6 multicast data packets 
in VLAN 100.  
[SwitchB-vlan100] mld-snooping enable 
[SwitchB-vlan100] mld-snooping drop-unknown 
[SwitchB-vlan100] quit 
Configurations of Switch C and Switch D are similar to the configuration of Switch B. 
3)  Verify the configuration 
When the MLD snooping querier starts to work, all the switches but the querier receive MLD general 
queries. Use the display mld-snooping statistics command to view the statistics information of these 
MLD messages received.  
# Display the MLD message statistics on Switch B.  
[SwitchB-vlan100] display mld-snooping statistics 
  Received MLD general queries:3. 
  Received MLDv1 specific queries:0. 
  Received MLDv1 reports:12. 
  Received MLD dones:0. 
  Sent     MLDv1 specific queries:0. 
  Received MLDv2 reports:0. 
  Received MLDv2 reports with right and wrong records:0. 
  Received MLDv2 specific queries:0. 
  Received MLDv2 specific sg queries:0. 
  Sent     MLDv2 specific queries:0. 
  Sent     MLDv2 specific sg queries:0. 
  Received error MLD messages:0. 
MLD Snooping Proxying Configuration Example 
Network requirements 
As shown in