3com S7906E 설치 설명서
1-37
# If Switch A fails, use the display vrrp verbose command to display the detailed information of VRRP
group 1 on Switch C.
[SwitchC-Vlan-interface2] display vrrp verbose
IPv4 Standby Information:
Run Mode : Load Balance
Run Method : Virtual MAC
Total number of virtual routers : 1
Interface Vlan-interface2
VRID : 1 Adver Timer : 1
Admin Status : Up State : Backup
Config Pri : 100 Running Pri : 100
Preempt Mode : Yes Delay Time : 5
Auth Type : None
Virtual IP : 10.1.1.1
Master IP : 10.1.1.3
Forwarder Information: 3 Forwarders 2 Active
Config Weight : 255
Running Weight : 255
Forwarder 01
State : Active
Virtual MAC : 000f-e2ff-0011 (Take Over)
Owner ID : 0000-5e01-1101
Priority : 85
Active : local
Redirect Time : 577 secs
Time-out Time : 1777 secs
Forwarder 02
State : Listening
Virtual MAC : 000f-e2ff-0012 (Learnt)
Owner ID : 0000-5e01-1103
Priority : 85
Active : 10.1.1.3
Forwarder 03
State : Active
Virtual MAC : 000f-e2ff-0013 (Owner)
Owner ID : 0000-5e01-1105
Priority : 255
Active : local
The above information indicates that if Switch A fails, Switch B becomes the master, Switch C becomes
the AVF among the VFs corresponding to the virtual MAC address 000f-e2ff-0011, and packets sent
from Host A to the external network are forwarded by Switch C.
IPv6-Based VRRP Configuration Examples
This section provides these configuration examples:
z
z