3com S7906E 설치 설명서

다운로드
페이지 2621
 
2-3 
The OLT can configure the following functions for the ONU: 
Basic port configurations, including duplex mode, rate, and traffic control.  
VLAN management and configuration 
Multicast 
QoS 
DBA 
The OLT can query and configure the functions mentioned above. You can use the related query 
commands to query the status of a function on the ONU. You can also configure parameters for a 
function on the OLT, and the OLT will issue the configured parameters to the ONU automatically. The 
query or configuration command is identified by the Ext.Opcode field in the Organization Specific 
OAMPDUs. The codes and configurations to be queried or configured are encapsulated in the payload 
field. For details, refer to 
.  
Configuring Extended OAM 
Enabling Extended OAM 
On an S7900E switch, you need not enable extend OAM manually; instead, extended OAM is enabled 
on a port automatically when you enable Ethernet OAM on the port.  
Configuring Extended OAM Discovery Timeout Time 
Extended OAM discovery timeout time refers to the timeout time of extended OAM messages 
exchanged between an OLT and its ONU during an extended OAM discovery process.  
Follow these steps to configure the extended OAM discovery timeout time: 
To do… 
Use the command… 
Remarks 
Enter system view 
system-view 
— 
Enter FTTH view 
ftth 
— 
Configure the extended OAM 
discovery timeout time 
oam-discovery-timeout value 
slot slot-number 
Optional 
The unit of measure for this 
parameter is 100 ms. The 
default value of this parameter 
is 30, that is, 3 seconds. 
 
 
You are recommended to use the default value of this parameter. 
If an OLT stays down after being bundled with an ONU port, you can change the extended OAM 
discovery timeout time to a larger value. 
 
Configuring Extended OAM Manageability 
For how to configure extended OAM manageability, refer to EPON-OLT Configuration.